Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains frequency
50/60 Hz
Number of phases input
3
Max. output at linear load at rated output voltage
5.5kW
Nominal output current I2N
9A
Number of phases output
3
Mains voltage
500 - 600V
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
5.5kW
Number of analogue inputs
2
Relative symmetric net frequency tolerance
10%
Power consumption
165W
Max. output frequency
500Hz
Number of analogue outputs
2
Max. output voltage
600V
Number of digital inputs
5
Application in industrial area permitted
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for TCP/IP
Yes
With control element
Yes
Supporting protocol for KNX
No
Supporting protocol for INTERBUS
No
Application in domestic- and commercial area permitted
Yes
Supporting protocol for CAN
Yes
Supporting protocol for ASI
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for SUCONET
No
Supporting protocol for Data-Highway
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for BACnet
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-232
0
Supporting protocol for Modbus
Yes
Number of digital outputs
2
With optical interface
No
Number of HW-interfaces other
0
With PC connection
Yes
Integrated breaking resistance
Yes
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Height
231mm
Width
107mm
Depth
186mm
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DA1-359D0NB-A20C

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains frequency
50/60 Hz
Number of phases input
3
Max. output at linear load at rated output voltage
5.5kW
Nominal output current I2N
9A
Number of phases output
3
Mains voltage
500 .. 600V
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
5.5kW
Number of analogue inputs
2
Relative symmetric net frequency tolerance
10%
Power consumption
165W
Max. output frequency
500Hz
Number of analogue outputs
2
Max. output voltage
600V
Number of digital inputs
5
Application in industrial area permitted
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
With control element
Supporting protocol for KNX
Supporting protocol for INTERBUS
Application in domestic- and commercial area permitted
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SUCONET
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for BACnet
Supporting protocol for other bus systems
Number of HW-interfaces industrial Ethernet
0
Number of interfaces PROFINET
0
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-232
0
Supporting protocol for Modbus
Number of digital outputs
2
With optical interface
Number of HW-interfaces other
0
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Height
231mm
Width
107mm
Depth
186mm
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
From same serie
Related products