- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output at quadratic load at rated output voltage
75kW
Mains voltage
500 - 600V
Nominal output current I2N
105A
Number of phases input
3
Number of phases output
3
Max. output voltage
600V
With control element
Yes
Relative symmetric net frequency tolerance
10%
Power consumption
2250W
Number of analogue outputs
2
Max. output frequency
500Hz
Max. output at linear load at rated output voltage
75kW
Number of analogue inputs
2
Supporting protocol for PROFIBUS
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for TCP/IP
Yes
Application in industrial area permitted
Yes
Supporting protocol for ASI
No
Number of digital outputs
2
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for LON
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for PROFINET CBA
No
Mains frequency
50/60 Hz
Number of digital inputs
5
Supporting protocol for SERCOS
No
Relative symmetric net voltage tolerance
10%
Supporting protocol for Modbus
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for KNX
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for CAN
Yes
Number of HW-interfaces other
0
With optical interface
No
With PC connection
Yes
4-quadrant operation possible
Yes
Integrated breaking resistance
Yes
Type of converter
U converter
Degree of protection (IP)
IP55
Degree of protection (NEMA)
12
Height
865mm
Depth
313.5mm
Width
330mm
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces USB
0
Supporting protocol for BACnet
No
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-422
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DA1-35105NB-B55C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output at quadratic load at rated output voltage
75kW
Mains voltage
500 .. 600V
Nominal output current I2N
105A
Number of phases input
3
Number of phases output
3
Max. output voltage
600V
With control element
Relative symmetric net frequency tolerance
10%
Power consumption
2250W
Number of analogue outputs
2
Max. output frequency
500Hz
Max. output at linear load at rated output voltage
75kW
Number of analogue inputs
2
Supporting protocol for PROFIBUS
Application in domestic- and commercial area permitted
Supporting protocol for TCP/IP
Application in industrial area permitted
Supporting protocol for ASI
Number of digital outputs
2
Supporting protocol for Foundation Fieldbus
Supporting protocol for LON
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Mains frequency
50/60 Hz
Number of digital inputs
5
Supporting protocol for SERCOS
Relative symmetric net voltage tolerance
10%
Supporting protocol for Modbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for KNX
Supporting protocol for Data-Highway
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for CAN
Number of HW-interfaces other
0
With optical interface
With PC connection
4-quadrant operation possible
Integrated breaking resistance
Type of converter
U converter
Degree of protection (IP)
IP55
Degree of protection (NEMA)
12
Height
865mm
Depth
313.5mm
Width
330mm
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for SafetyBUS p
Number of HW-interfaces USB
0
Supporting protocol for BACnet
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-422
0