Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Supporting protocol for TCP/IP
Yes
Number of digital outputs
2
Number of analogue outputs
2
Nominal output current I2N
28A
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
2
Max. output at quadratic load at rated output voltage
15kW
With control element
Yes
Number of phases output
3
Supporting protocol for CAN
Yes
Relative symmetric net frequency tolerance
10%
Power consumption
555W
Supporting protocol for DeviceNet
Yes
Mains voltage
500 - 600V
Number of digital inputs
5
Application in industrial area permitted
Yes
Supporting protocol for LON
No
Supporting protocol for KNX
No
Supporting protocol for SUCONET
No
Supporting protocol for INTERBUS
No
Max. output at linear load at rated output voltage
15kW
Supporting protocol for PROFINET IO
Yes
Max. output voltage
600V
Mains frequency
50/60 Hz
Supporting protocol for Data-Highway
No
Number of phases input
3
Supporting protocol for PROFIBUS
Yes
Max. output frequency
500Hz
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
Yes
Type of converter
U converter
4-quadrant operation possible
Yes
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Height
419mm
Width
173mm
Depth
241mm
Supporting protocol for Modbus
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for other bus systems
Yes
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
No
Number of HW-interfaces serial TTY
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DA1-35028NB-B20C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Supporting protocol for TCP/IP
Number of digital outputs
2
Number of analogue outputs
2
Nominal output current I2N
28A
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
2
Max. output at quadratic load at rated output voltage
15kW
With control element
Number of phases output
3
Supporting protocol for CAN
Relative symmetric net frequency tolerance
10%
Power consumption
555W
Supporting protocol for DeviceNet
Mains voltage
500 .. 600V
Number of digital inputs
5
Application in industrial area permitted
Supporting protocol for LON
Supporting protocol for KNX
Supporting protocol for SUCONET
Supporting protocol for INTERBUS
Max. output at linear load at rated output voltage
15kW
Supporting protocol for PROFINET IO
Max. output voltage
600V
Mains frequency
50/60 Hz
Supporting protocol for Data-Highway
Number of phases input
3
Supporting protocol for PROFIBUS
Max. output frequency
500Hz
With optical interface
With PC connection
Integrated breaking resistance
Type of converter
U converter
4-quadrant operation possible
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Height
419mm
Width
173mm
Depth
241mm
Supporting protocol for Modbus
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for other bus systems
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
Number of HW-interfaces serial TTY
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Supporting protocol for SafetyBUS p
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
0
From same serie
Related products