![Main Product Image](https://assets.aleta.hr/415x415/db75ceda-b52f-4777-96e9-203cf0a2e4d7.webp)
![Main Product Image](https://assets.aleta.hr/415x415/db75ceda-b52f-4777-96e9-203cf0a2e4d7.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 - 480V
Mains frequency
50/60 Hz
Max. output at quadratic load at rated output voltage
1.5kW
Number of analogue inputs
2
Nominal output current I2N
4.1A
Max. output frequency
500Hz
Max. output voltage
500V
Number of phases input
3
Power consumption
76.5W
Number of phases output
3
Number of digital outputs
2
Max. output at linear load at rated output voltage
1.5kW
Relative symmetric net voltage tolerance
10%
Number of digital inputs
5
Relative symmetric net frequency tolerance
10%
Supporting protocol for KNX
No
Supporting protocol for CAN
Yes
Number of analogue outputs
2
Supporting protocol for INTERBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
Yes
Supporting protocol for TCP/IP
Yes
With control element
Yes
Supporting protocol for LON
No
Application in industrial area permitted
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for SUCONET
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for PROFINET IO
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Number of HW-interfaces other
0
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
Yes
Degree of protection (IP)
IP20
Type of converter
U converter
4-quadrant operation possible
Yes
Degree of protection (NEMA)
Other
Width
107mm
Height
231mm
Depth
186mm
Supporting protocol for SafetyBUS p
No
Number of interfaces PROFINET
0
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Supporting protocol for other bus systems
Yes
Number of HW-interfaces parallel
0
Supporting protocol for BACnet
No
Number of HW-interfaces serial TTY
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DA1-344D1FB-A20C
![Main Product Image](https://assets.aleta.hr/300x300/f609f080-2c53-44b9-b3ce-6d9571a58679_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 .. 480V
Mains frequency
50/60 Hz
Max. output at quadratic load at rated output voltage
1.5kW
Number of analogue inputs
2
Nominal output current I2N
4.1A
Max. output frequency
500Hz
Max. output voltage
500V
Number of phases input
3
Power consumption
76.5W
Number of phases output
3
Number of digital outputs
2
Max. output at linear load at rated output voltage
1.5kW
Relative symmetric net voltage tolerance
10%
Number of digital inputs
5
Relative symmetric net frequency tolerance
10%
Supporting protocol for KNX
Supporting protocol for CAN
Number of analogue outputs
2
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for TCP/IP
With control element
Supporting protocol for LON
Application in industrial area permitted
Application in domestic- and commercial area permitted
Supporting protocol for SUCONET
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Number of HW-interfaces other
0
With optical interface
With PC connection
Integrated breaking resistance
Degree of protection (IP)
IP20
Type of converter
U converter
4-quadrant operation possible
Degree of protection (NEMA)
Other
Width
107mm
Height
231mm
Depth
186mm
Supporting protocol for SafetyBUS p
Number of interfaces PROFINET
0
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Supporting protocol for other bus systems
Number of HW-interfaces parallel
0
Supporting protocol for BACnet
Number of HW-interfaces serial TTY
0
From same serie
Related products
We use cookies to enhance your experience.