Details
- Relays
- Voltage monitoring relay
- 1 KOM
- EATON
Technical specifications
With detachable clamps
No
Voltage type of supply voltage
AC/DC
Supply voltage AC 50 Hz
24 - 240V
Type of electric connection
Screw connection
Supply voltage DC
24 - 240V
Supply voltage AC 60 Hz
24 - 240V
Voltage measuring range 2
0 - 0V
Single-phase under voltage possible
Yes
Voltage measuring range 1
3 - 600V
Type of voltage measuring range
AC/DC
Three-phase under voltage possible
No
Single-phase over voltage possible
Yes
Contains function DC-under voltage
Yes
Single-phase hysteresis possible
No
Three-phase hysteresis possible
No
Three-phase over voltage possible
No
Response value voltage
3 - 600V
Contains function DC-over voltage
Yes
Min. adjustable off-delay time
0s
Max. permitted delay-on energization time
30s
Max. permitted off-delay time
0s
Min. adjustable delay-on energization time
0.1s
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
2
Contains function DC-voltage hysteresis
No
Rated switch current
4A
Operating voltage at DC
24 - 240V
Height
85.6mm
Operating voltage at AC 50 Hz
24 - 240V
Width
22.5mm
Operating voltage at AC 60 Hz
24 - 240V
Voltage type (operating voltage)
AC/DC
Depth
103.7mm
External power supply required
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
EMR6-VM600-A-1

Details
- Relays
- Voltage monitoring relay
- 1 KOM
- EATON
Technical specifications
With detachable clamps
Voltage type of supply voltage
AC/DC
Supply voltage AC 50 Hz
24 .. 240V
Type of electric connection
Screw connection
Supply voltage DC
24 .. 240V
Supply voltage AC 60 Hz
24 .. 240V
Voltage measuring range 2
0 .. 0V
Single-phase under voltage possible
Voltage measuring range 1
3 .. 600V
Type of voltage measuring range
AC/DC
Three-phase under voltage possible
Single-phase over voltage possible
Contains function DC-under voltage
Single-phase hysteresis possible
Three-phase hysteresis possible
Three-phase over voltage possible
Response value voltage
3 .. 600V
Contains function DC-over voltage
Min. adjustable off-delay time
0s
Max. permitted delay-on energization time
30s
Max. permitted off-delay time
0s
Min. adjustable delay-on energization time
0.1s
Number of contacts as normally closed contact
0
Number of contacts as normally open contact
0
Number of contacts as change-over contact
2
Contains function DC-voltage hysteresis
Rated switch current
4A
Operating voltage at DC
24 .. 240V
Height
85.6mm
Operating voltage at AC 50 Hz
24 .. 240V
Width
22.5mm
Operating voltage at AC 60 Hz
24 .. 240V
Voltage type (operating voltage)
AC/DC
Depth
103.7mm
External power supply required
From same serie