Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
No
System configuration IT
No
System configuration TN
Yes
System configuration TT
No
System configuration TN-C
Yes
System configuration TN-C-S
Yes
System configuration TN-S
No
System configuration other
No
Number of poles
3
Lightning impulse current (10/350 µs)
25kA
Max. continuous voltage AC
350V
Nominal voltage AC
240V
Max. PV-voltage
0V
Nominal voltage DC
0V
Voltage protection level
1.5kV
Max. continuous voltage DC
0V
Voltage protection level L-N
1.5kV
Voltage protection level N-PE
0kV
Voltage protection level (DC+ - DC-)
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Follow current extinguishing capability
50kA
Specific energy (W/R)
160kJ/Ohm
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level L-PE
0kV
Construction size
6 modular spacing
Max. conductor cross section solid (solid, stranded)
35mm²
Signalling at the device
Optic
Energy-coordinated protection effect with regard to the terminal equipment
Yes
Remote signalling
Yes
Max. overcurrent protection device, series connection (fuse)
315A
Voltage switching spark gap technology
No
Max. conductor cross section flexible (fine-strand)
35mm²
Mounting method
DIN rail (top hat rail) 35 mm
Test class
Type 1 + 2
Degree of protection (IP)
IP20
Integrated backup fuse
No
Overcurrent protected voltage tapping
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPRT12-350/3-AX

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
System configuration IT
System configuration TN
System configuration TT
System configuration TN-C
System configuration TN-C-S
System configuration TN-S
System configuration other
Number of poles
3
Lightning impulse current (10/350 µs)
25kA
Max. continuous voltage AC
350V
Nominal voltage AC
240V
Max. PV-voltage
0V
Nominal voltage DC
0V
Voltage protection level
1.5kV
Max. continuous voltage DC
0V
Voltage protection level L-N
1.5kV
Voltage protection level N-PE
0kV
Voltage protection level (DC+ - DC-)
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Follow current extinguishing capability
50kA
Specific energy (W/R)
160kJ/Ohm
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level L-PE
0kV
Construction size
6 modular spacing
Max. conductor cross section solid (solid, stranded)
35mm²
Signalling at the device
Optic
Energy-coordinated protection effect with regard to the terminal equipment
Remote signalling
Max. overcurrent protection device, series connection (fuse)
315A
Voltage switching spark gap technology
Max. conductor cross section flexible (fine-strand)
35mm²
Mounting method
DIN rail (top hat rail) 35 mm
Test class
Type 1 + 2
Degree of protection (IP)
IP20
Integrated backup fuse
Overcurrent protected voltage tapping