Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as reversing switch
No
Version as emergency stop installation
Yes
Rated permanent current Iu
20A
Version as maintenance-/service switch
Yes
Version as safety switch
Yes
Number of switches
1
Rated permanent current at AC-23, 400 V
13.3A
Rated operating voltage
690 - 690V
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current at AC-21, 400 V
20A
Rated short-time withstand current lcw
0.32kA
Conditioned rated short-circuit current Iq
6kA
Rated operation power at AC-23, 400 V
5.5kW
Number of poles
6
Version as main switch
Yes
Switching power at 400 V
5.5kW
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Motor drive optional
No
Motor drive integrated
No
Device construction
Complete device in housing
Voltage release optional
No
Suitable for front mounting centre
No
Suitable for front mounting 4-hole
No
Suitable for intermediate mounting
No
Suitable for distribution board installation
No
Interlockable
Yes
Degree of protection (NEMA)
12
With pre-assembled cabling
No
Colour control element
Red
Suitable for floor mounting
Yes
Type of control element
Door coupling rotary drive
Width
200mm
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Height
155mm
Depth
250mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
T0-4-15682/SE2/SVB

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as reversing switch
Version as emergency stop installation
Rated permanent current Iu
20A
Version as maintenance-/service switch
Version as safety switch
Number of switches
1
Rated permanent current at AC-23, 400 V
13.3A
Rated operating voltage
690 .. 690V
Rated operation power at AC-3, 400 V
5.5kW
Rated permanent current at AC-21, 400 V
20A
Rated short-time withstand current lcw
0.32kA
Conditioned rated short-circuit current Iq
6kA
Rated operation power at AC-23, 400 V
5.5kW
Number of poles
6
Version as main switch
Switching power at 400 V
5.5kW
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
1
Number of auxiliary contacts as normally open contact
1
Motor drive optional
Motor drive integrated
Device construction
Complete device in housing
Voltage release optional
Suitable for front mounting centre
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Suitable for distribution board installation
Interlockable
Degree of protection (NEMA)
12
With pre-assembled cabling
Colour control element
Red
Suitable for floor mounting
Type of control element
Door coupling rotary drive
Width
200mm
Degree of protection (IP), front side
IP65
Type of electrical connection of main circuit
Screw connection
Height
155mm
Depth
250mm
From same serie