Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C-S
No
System configuration other
No
System configuration TT
No
System configuration DC
No
System configuration IT
No
System configuration TN-C
No
Nominal voltage DC
0V
Lightning impulse current (10/350 µs)
25kA
Voltage protection level
1.5kV
System configuration TN
Yes
Voltage protection level L-N
1.5kV
Nominal voltage AC
240V
Number of poles
0
Max. continuous voltage DC
0V
Specific energy (W/R)
160kJ/Ohm
Voltage protection level L-PE
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Follow current extinguishing capability
50kA
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
315A
Remote signalling
No
Signalling at the device
Optic
System configuration TN-S
No
Construction size
2 modular spacing
Mounting method
On basic element
Voltage protection level N-PE
0kV
Voltage protection level (DC+ - DC-)
0kV
Max. conductor cross section flexible (fine-strand)
0mm²
Max. conductor cross section solid (solid, stranded)
0mm²
Max. PV-voltage
0V
Max. continuous voltage AC
350V
Integrated backup fuse
No
Test class
Type 1 + 2
Energy-coordinated protection effect with regard to the terminal equipment
Yes
Voltage switching spark gap technology
No
Degree of protection (IP)
IP20
Overcurrent protected voltage tapping
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPRT12-350

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C-S
System configuration other
System configuration TT
System configuration DC
System configuration IT
System configuration TN-C
Nominal voltage DC
0V
Lightning impulse current (10/350 µs)
25kA
Voltage protection level
1.5kV
System configuration TN
Voltage protection level L-N
1.5kV
Nominal voltage AC
240V
Number of poles
0
Max. continuous voltage DC
0V
Specific energy (W/R)
160kJ/Ohm
Voltage protection level L-PE
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Follow current extinguishing capability
50kA
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
315A
Remote signalling
Signalling at the device
Optic
System configuration TN-S
Construction size
2 modular spacing
Mounting method
On basic element
Voltage protection level N-PE
0kV
Voltage protection level (DC+ - DC-)
0kV
Max. conductor cross section flexible (fine-strand)
0mm²
Max. conductor cross section solid (solid, stranded)
0mm²
Max. PV-voltage
0V
Max. continuous voltage AC
350V
Integrated backup fuse
Test class
Type 1 + 2
Energy-coordinated protection effect with regard to the terminal equipment
Voltage switching spark gap technology
Degree of protection (IP)
IP20
Overcurrent protected voltage tapping
From same serie
We use cookies to enhance your experience.