E57PS-18SPN5-C2
Code: 1863446
Code: 1863446
Voltage type
DC
Material housing
Metal
Rated control supply voltage Us at DC
10 - 30V
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Type of electric connection
Cable
Explosion safety category for dust
None
Length of sensor
65.9mm
Construction type housing
Cylinder, screw-thread
Width sensor
0mm
Diameter sensor
18mm
Type of interface for safety communication
None
Type of interface
None
Coating housing
Other
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
With monitoring function downstream switching devices
No
Number of protected semiconductor outputs
0
Switching frequency
1200Hz
Category according to EN 954-1
B
Supply voltage
10 - 30V
Max. output current at protected output
0mA
Number of semiconductor outputs with signalling function
1
Type of switching output
PNP
Type of switch function
Normally open contact
Suitable for safety functions
No
Explosion safety category for gas
None
Height of sensor
0mm
Number of protected contact energized outputs
0
Number of contact energized outputs with signalling function
0
Type of actuation
Metallic Target
Switching distance
5mm
Cascadable
No
Mechanical mounting condition for sensor
Concise
Compression-resistant
No
Zagreb:
0 pcs
Zadar:
0 pcs
E57PS-18SPN5-C2
Voltage type
DC
Material housing
Metal
Rated control supply voltage Us at DC
10 .. 30V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Type of electric connection
Cable
Explosion safety category for dust
None
Length of sensor
65.9mm
Construction type housing
Cylinder, screw-thread
Width sensor
0mm
Diameter sensor
18mm
Type of interface for safety communication
None
Type of interface
None
Coating housing
Other
Performance level according to EN ISO 13849-1
None
SIL according to IEC 61508
None
With monitoring function downstream switching devices
Number of protected semiconductor outputs
0
Switching frequency
1200Hz
Category according to EN 954-1
B
Supply voltage
10 .. 30V
Max. output current at protected output
0mA
Number of semiconductor outputs with signalling function
1
Type of switching output
PNP
Type of switch function
Normally open contact
Suitable for safety functions
Explosion safety category for gas
None
Height of sensor
0mm
Number of protected contact energized outputs
0
Number of contact energized outputs with signalling function
0
Type of actuation
Metallic Target
Switching distance
5mm
Cascadable
Mechanical mounting condition for sensor
Concise
Compression-resistant