Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
With short-circuit release
No
Rated control supply voltage Us at DC
24 - 24V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Voltage type for actuating
DC
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated operation current Ie
9A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation power at AC-3, 400 V
3kW
Overload release current setting
1.5 - 9A
Rated operation current at AC-3, 400 V
6.5A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 2, 400 V
0A
Power consumption
12W
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
0A
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Yes
Ambient temperature, upper operating limit
55°C
Rail mounting possible
Yes
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Type of electrical connection of main circuit
Spring clamp connection
With transformer
No
Supporting protocol for INTERBUS
No
Supporting protocol for SERCOS
No
Number of command positions
0
Supporting protocol for Data-Highway
No
Suitable for emergency stop
No
Supporting protocol for SUCONET
No
Coordination class according to IEC 60947-4-3
Class 1
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet
No
With fuse
No
Supporting protocol for CAN
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for EtherNet/IP
No
External reset possible
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Modbus
No
Number of indicator lights
0
Degree of protection (IP)
IP20
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
Yes
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Width
22.5mm
Height
99mm
Depth
114.5mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
EMS2-RO-T-9-SWD

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
With short-circuit release
Rated control supply voltage Us at DC
24 .. 24V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Voltage type for actuating
DC
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation current Ie
9A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation power at AC-3, 400 V
3kW
Overload release current setting
1.5 .. 9A
Rated operation current at AC-3, 400 V
6.5A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 2, 400 V
0A
Power consumption
12W
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 230 V
0A
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Ambient temperature, upper operating limit
55°C
Rail mounting possible
Release class
CLASS 10 A
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Type of electrical connection of main circuit
Spring clamp connection
With transformer
Supporting protocol for INTERBUS
Supporting protocol for SERCOS
Number of command positions
0
Supporting protocol for Data-Highway
Suitable for emergency stop
Supporting protocol for SUCONET
Coordination class according to IEC 60947-4-3
Class 1
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet
With fuse
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for EtherNet/IP
External reset possible
Supporting protocol for Foundation Fieldbus
Supporting protocol for Modbus
Number of indicator lights
0
Degree of protection (IP)
IP20
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for LON
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Width
22.5mm
Height
99mm
Depth
114.5mm
From same serie
Related products
We use cookies to enhance your experience.