Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
With short-circuit release
No
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at DC
24 - 24V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current at AC-3, 400 V
6.5A
Temperature compensated overload protection
Yes
Ambient temperature, upper operating limit
70°C
Power consumption
14.6W
Number of auxiliary contacts as normally closed contact
1
Release class
CLASS 10
Rated conditional short-circuit current, type 2, 400 V
0A
With transformer
No
Type of electrical connection of main circuit
Screw connection
Rail mounting possible
Yes
Number of auxiliary contacts as normally open contact
1
Voltage type for actuating
DC
Suitable for emergency stop
No
Number of command positions
0
With fuse
No
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Coordination class according to IEC 60947-4-3
Class 1
Degree of protection (IP)
IP20
Number of indicator lights
0
Rated operation current Ie
9A
Supporting protocol for TCP/IP
No
Degree of protection (NEMA)
Other
Overload release current setting
1.5 - 9A
Supporting protocol for CAN
No
Rated operation power at AC-3, 400 V
3kW
Rated conditional short-circuit current, type 2, 230 V
0A
Supporting protocol for INTERBUS
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
External reset possible
No
Supporting protocol for PROFIBUS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
22.5mm
Height
99mm
Depth
114.5mm
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET IO
No
Supporting protocol for ASI
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFIsafe
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
EMS2-RO-Z-9-24VDC

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Reversing starter
With short-circuit release
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at DC
24 .. 24V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation current at AC-3, 400 V
6.5A
Temperature compensated overload protection
Ambient temperature, upper operating limit
70°C
Power consumption
14.6W
Number of auxiliary contacts as normally closed contact
1
Release class
CLASS 10
Rated conditional short-circuit current, type 2, 400 V
0A
With transformer
Type of electrical connection of main circuit
Screw connection
Rail mounting possible
Number of auxiliary contacts as normally open contact
1
Voltage type for actuating
DC
Suitable for emergency stop
Number of command positions
0
With fuse
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Coordination class according to IEC 60947-4-3
Class 1
Degree of protection (IP)
IP20
Number of indicator lights
0
Rated operation current Ie
9A
Supporting protocol for TCP/IP
Degree of protection (NEMA)
Other
Overload release current setting
1.5 .. 9A
Supporting protocol for CAN
Rated operation power at AC-3, 400 V
3kW
Rated conditional short-circuit current, type 2, 230 V
0A
Supporting protocol for INTERBUS
Type of electrical connection for auxiliary- and control current circuit
Screw connection
External reset possible
Supporting protocol for PROFIBUS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
22.5mm
Height
99mm
Depth
114.5mm
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supporting protocol for ASI
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
From same serie