EMS2-RO-Z-2,4-24VDC

Code: 1862935

ManufacturerRAZNO
Catalog number197161
Type
EAN code4015080896029

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Reversing starter

Rated control supply voltage Us at DC

24 - 24V

With short-circuit release

No

Rated control supply voltage Us at AC 60HZ

0 - 0V

Voltage type for actuating

DC

Rated control supply voltage Us at AC 50HZ

0 - 0V

Rated operation power at AC-3, 400 V

0.75kW

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated operation current Ie

2.4A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Overload release current setting

0.18 - 3A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current at AC-3, 400 V

2.4A

Power consumption

4.1W

Number of auxiliary contacts as normally closed contact

1

Rated conditional short-circuit current, type 2, 230 V

0A

Ambient temperature, upper operating limit

60°C

Number of auxiliary contacts as normally open contact

1

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated conditional short-circuit current, type 2, 400 V

0A

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10

Temperature compensated overload protection

Yes

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 1

Rail mounting possible

Yes

With transformer

No

With fuse

No

Suitable for emergency stop

No

Number of indicator lights

0

Degree of protection (IP)

IP20

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Supporting protocol for SafetyBUS p

No

Width

22.5mm

Height

99mm

Depth

114.5mm

External reset possible

No

Supporting protocol for TCP/IP

No

Degree of protection (NEMA)

Other

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

Supporting protocol for INTERBUS

No

Supporting protocol for Modbus

No

Supporting protocol for ASI

No

Supporting protocol for DeviceNet

No

Supporting protocol for Data-Highway

No

Supporting protocol for SUCONET

No

Supporting protocol for LON

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Foundation Fieldbus

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

Code: 1862935

EMS2-RO-Z-2,4-24VDC

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Reversing starter

Rated control supply voltage Us at DC

24 .. 24V

With short-circuit release

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Voltage type for actuating

DC

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated operation power at AC-3, 400 V

0.75kW

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated operation current Ie

2.4A

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated power, 575 V, 60 Hz, 3-phase

0kW

Overload release current setting

0.18 .. 3A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current at AC-3, 400 V

2.4A

Power consumption

4.1W

Number of auxiliary contacts as normally closed contact

1

Rated conditional short-circuit current, type 2, 230 V

0A

Ambient temperature, upper operating limit

60°C

Number of auxiliary contacts as normally open contact

1

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Rated conditional short-circuit current, type 2, 400 V

0A

Type of electrical connection of main circuit

Screw connection

Release class

CLASS 10

Temperature compensated overload protection

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 1

Rail mounting possible

With transformer

With fuse

Suitable for emergency stop

Number of indicator lights

0

Degree of protection (IP)

IP20

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Width

22.5mm

Height

99mm

Depth

114.5mm

External reset possible

Supporting protocol for TCP/IP

Degree of protection (NEMA)

Other

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.