- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
No
Type of motor starter
Reversing starter
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Voltage type for actuating
DC
Rated operation current at AC-3, 400 V
2.4A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated operation current Ie
2.4A
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 400 V
0A
Rated operation power at AC-3, 400 V
0.75kW
Number of auxiliary contacts as normally closed contact
1
Power consumption
3.3W
Temperature compensated overload protection
Yes
Ambient temperature, upper operating limit
70°C
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Release class
CLASS 10
Rail mounting possible
Yes
Rated power, 575 V, 60 Hz, 3-phase
0kW
Overload release current setting
0.18 - 3A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Type of electrical connection of main circuit
Spring clamp connection
Number of auxiliary contacts as normally open contact
1
Rated control supply voltage Us at DC
24 - 24V
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
22.5mm
Depth
114.5mm
Height
99mm
Suitable for emergency stop
No
With transformer
No
Number of command positions
0
With fuse
No
External reset possible
No
Degree of protection (NEMA)
Other
Number of indicator lights
0
Supporting protocol for INTERBUS
No
Degree of protection (IP)
IP20
Supporting protocol for ASI
No
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for TCP/IP
No
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for PROFIBUS
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SUCONET
No
Supporting protocol for CAN
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
EMS2-RO-T-2,4-24VDC

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Type of motor starter
Reversing starter
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Voltage type for actuating
DC
Rated operation current at AC-3, 400 V
2.4A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation current Ie
2.4A
Rated conditional short-circuit current, type 2, 230 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated conditional short-circuit current, type 2, 400 V
0A
Rated operation power at AC-3, 400 V
0.75kW
Number of auxiliary contacts as normally closed contact
1
Power consumption
3.3W
Temperature compensated overload protection
Ambient temperature, upper operating limit
70°C
Type of electrical connection for auxiliary- and control current circuit
Spring clamp connection
Release class
CLASS 10
Rail mounting possible
Rated power, 575 V, 60 Hz, 3-phase
0kW
Overload release current setting
0.18 .. 3A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Type of electrical connection of main circuit
Spring clamp connection
Number of auxiliary contacts as normally open contact
1
Rated control supply voltage Us at DC
24 .. 24V
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
22.5mm
Depth
114.5mm
Height
99mm
Suitable for emergency stop
With transformer
Number of command positions
0
With fuse
External reset possible
Degree of protection (NEMA)
Other
Number of indicator lights
0
Supporting protocol for INTERBUS
Degree of protection (IP)
IP20
Supporting protocol for ASI
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for TCP/IP
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for PROFIBUS
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
Supporting protocol for CAN
From same serie
Related products
We use cookies to enhance your experience.