Technical specifications
Type of motor starter
Direct online starter (DOL)
With short-circuit release
No
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at DC
24 - 24V
Voltage type for actuating
DC
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Power consumption
3.3W
Rated conditional short-circuit current, type 2, 400 V
0A
Release class
CLASS 10
Rated operation current at AC-3, 400 V
2.4A
Type of electrical connection of main circuit
Screw connection
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Number of auxiliary contacts as normally closed contact
1
Rail mounting possible
Yes
Overload release current setting
0.18 - 3A
Suitable for emergency stop
No
Number of auxiliary contacts as normally open contact
1
Number of indicator lights
0
Rated operation power at AC-3, 400 V
0.75kW
Coordination class according to IEC 60947-4-3
Class 1
Rated operation current Ie
2.4A
Rated conditional short-circuit current, type 2, 230 V
0A
Temperature compensated overload protection
Yes
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
No
Rated control supply voltage Us at AC 60HZ
0 - 0V
External reset possible
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for Modbus
No
Supporting protocol for TCP/IP
No
With fuse
No
Supporting protocol for PROFINET CBA
No
Degree of protection (IP)
IP20
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Number of command positions
0
Supporting protocol for PROFINET IO
No
Supporting protocol for CAN
No
Supporting protocol for EtherNet/IP
No
Ambient temperature, upper operating limit
70°C
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Width
22.5mm
Supporting protocol for other bus systems
No
Depth
114.5mm
Height
99mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
Code: 1862914
EMS2-DO-Z-2,4-24VDC

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Rated operation power at AC-3, 230 V, 3-phase
0.37kW
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at DC
24 .. 24V
Voltage type for actuating
DC
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Power consumption
3.3W
Rated conditional short-circuit current, type 2, 400 V
0A
Release class
CLASS 10
Rated operation current at AC-3, 400 V
2.4A
Type of electrical connection of main circuit
Screw connection
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Number of auxiliary contacts as normally closed contact
1
Rail mounting possible
Overload release current setting
0.18 .. 3A
Suitable for emergency stop
Number of auxiliary contacts as normally open contact
1
Number of indicator lights
0
Rated operation power at AC-3, 400 V
0.75kW
Coordination class according to IEC 60947-4-3
Class 1
Rated operation current Ie
2.4A
Rated conditional short-circuit current, type 2, 230 V
0A
Temperature compensated overload protection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
Rated control supply voltage Us at AC 60HZ
0 .. 0V
External reset possible
Supporting protocol for INTERBUS
Supporting protocol for ASI
Degree of protection (NEMA)
Other
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for Modbus
Supporting protocol for TCP/IP
With fuse
Supporting protocol for PROFINET CBA
Degree of protection (IP)
IP20
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Number of command positions
0
Supporting protocol for PROFINET IO
Supporting protocol for CAN
Supporting protocol for EtherNet/IP
Ambient temperature, upper operating limit
70°C
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Width
22.5mm
Supporting protocol for other bus systems
Depth
114.5mm
Height
99mm