Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
No
Type of motor starter
Reversing starter
Rated control supply voltage Us at DC
24 - 24V
Voltage type for actuating
DC
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated operation current Ie
3A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
0.18 - 3A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
3A
Rated operation power at AC-3, 400 V
1.1kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 230 V, 3-phase
0.55kW
Rated conditional short-circuit current, type 2, 400 V
0A
Rated conditional short-circuit current, type 2, 230 V
0A
Number of auxiliary contacts as normally open contact
1
Type of electrical connection of main circuit
Screw connection
Power consumption
3.5W
Temperature compensated overload protection
Yes
Release class
CLASS 10
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Yes
Ambient temperature, upper operating limit
70°C
Coordination class according to IEC 60947-4-3
Class 2
With transformer
No
Degree of protection (IP)
IP20
Number of command positions
0
External reset possible
No
Supporting protocol for Modbus
No
Suitable for emergency stop
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Number of indicator lights
0
With fuse
Yes
Supporting protocol for INTERBUS
No
Degree of protection (NEMA)
Other
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for LON
No
Supporting protocol for TCP/IP
No
Supporting protocol for SERCOS
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for DeviceNet
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
22.5mm
Height
160mm
Depth
114.5mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
EMS2-ROSF-Z-3-24VDC

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
With short-circuit release
Type of motor starter
Reversing starter
Rated control supply voltage Us at DC
24 .. 24V
Voltage type for actuating
DC
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation current Ie
3A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
0.18 .. 3A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
3A
Rated operation power at AC-3, 400 V
1.1kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Number of auxiliary contacts as normally closed contact
1
Rated operation power at AC-3, 230 V, 3-phase
0.55kW
Rated conditional short-circuit current, type 2, 400 V
0A
Rated conditional short-circuit current, type 2, 230 V
0A
Number of auxiliary contacts as normally open contact
1
Type of electrical connection of main circuit
Screw connection
Power consumption
3.5W
Temperature compensated overload protection
Release class
CLASS 10
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Ambient temperature, upper operating limit
70°C
Coordination class according to IEC 60947-4-3
Class 2
With transformer
Degree of protection (IP)
IP20
Number of command positions
0
External reset possible
Supporting protocol for Modbus
Suitable for emergency stop
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Number of indicator lights
0
With fuse
Supporting protocol for INTERBUS
Degree of protection (NEMA)
Other
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for LON
Supporting protocol for TCP/IP
Supporting protocol for SERCOS
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
22.5mm
Height
160mm
Depth
114.5mm
From same serie
Related products
We use cookies to enhance your experience.