Aleta.hr
Main Product Image

FAZ-C2/4-RT

Code: 1862281

ManufacturerRAZNO
Catalog number190866
Type
EAN code4015081905133

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

60mm

Rated voltage

240V

Rated insulation voltage Ui

440V

Number of poles (total)

4

Rated current

2A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 - 50Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Power loss

5.6W

Flush-mounted installation

Yes

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Voltage type

AC

Release characteristic

C

Concurrently switching neutral conductor

No

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

1 - 25mm²

Ambient temperature during operating

-25 - 75°C

Explosion-proof

No

Additional equipment possible

Yes

Connectable conductor cross section solid-core

1 - 25mm²

Pollution degree

2


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FAZ-C2/4-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

60mm

Rated voltage

240V

Rated insulation voltage Ui

440V

Number of poles (total)

4

Rated current

2A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 50Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Power loss

5.6W

Flush-mounted installation

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Voltage type

AC

Release characteristic

C

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Additional equipment possible

Connectable conductor cross section solid-core

1 .. 25mm²

Pollution degree

2

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.