Aleta.hr
Main Product Image

FAZ-B25/4-RT

Code: 1862258

ManufacturerRAZNO
Catalog number190858
Type
EAN code4015081905058

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Number of protected poles

4

Rated impulse withstand voltage Uimp

4kV

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated insulation voltage Ui

440V

Built-in depth

60mm

Rated current

25A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Yes

Frequency

50 - 50Hz

Additional equipment possible

Yes

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

11.2W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Pollution degree

2

Concurrently switching neutral conductor

No

Over voltage category

3

Width in number of modular spacings

4

Ambient temperature during operating

-25 - 75°C

Explosion-proof

No

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 - 25mm²

Number of poles (total)

4

Connectable conductor cross section solid-core

1 - 25mm²

Voltage type

AC


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FAZ-B25/4-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Number of protected poles

4

Rated impulse withstand voltage Uimp

4kV

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated insulation voltage Ui

440V

Built-in depth

60mm

Rated current

25A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Frequency

50 .. 50Hz

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Power loss

11.2W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Pollution degree

2

Concurrently switching neutral conductor

Over voltage category

3

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 75°C

Explosion-proof

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

4

Connectable conductor cross section solid-core

1 .. 25mm²

Voltage type

AC

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.