Aleta.hr
Main Product Image

FAZ-B20/4-RT

Code: 1862257

ManufacturerRAZNO
Catalog number190857
Type
EAN code4015081905041

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

4

Number of protected poles

4

Built-in depth

60mm

Release characteristic

B

Rated insulation voltage Ui

440V

Rated voltage

240V

Rated current

20A

Rated impulse withstand voltage Uimp

4kV

Power loss

13.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Yes

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Additional equipment possible

Yes

Explosion-proof

No

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 - 25mm²

Current limiting class

3

Ambient temperature during operating

-25 - 75°C

Frequency

50 - 50Hz

Concurrently switching neutral conductor

No

Over voltage category

3

Voltage type

AC

Connectable conductor cross section solid-core

1 - 25mm²

Width in number of modular spacings

4


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FAZ-B20/4-RT

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of poles (total)

4

Number of protected poles

4

Built-in depth

60mm

Release characteristic

B

Rated insulation voltage Ui

440V

Rated voltage

240V

Rated current

20A

Rated impulse withstand voltage Uimp

4kV

Power loss

13.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Additional equipment possible

Explosion-proof

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 25mm²

Current limiting class

3

Ambient temperature during operating

-25 .. 75°C

Frequency

50 .. 50Hz

Concurrently switching neutral conductor

Over voltage category

3

Voltage type

AC

Connectable conductor cross section solid-core

1 .. 25mm²

Width in number of modular spacings

4

From same serie