Aleta.hr
Main Product Image

FAZ-C50/2-NA

Code: 1862205

ManufacturerRAZNO
Catalog number190785
Type
EAN code4015081930555

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

50A

Built-in depth

60mm

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Flush-mounted installation

Yes

Current limiting class

3

Power loss

8.8W

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

No

Explosion-proof

No

Connectable conductor cross section multi-wired

1 - 25mm²

Width in number of modular spacings

2

Voltage type

AC

Pollution degree

2

Ambient temperature during operating

-25 - 75°C

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Frequency

50 - 50Hz

Connectable conductor cross section solid-core

1 - 25mm²

Additional equipment possible

Yes

Over voltage category

3

Degree of protection (IP)

IP20


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

FAZ-C50/2-NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

50A

Built-in depth

60mm

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

14kA

Flush-mounted installation

Current limiting class

3

Power loss

8.8W

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 25mm²

Width in number of modular spacings

2

Voltage type

AC

Pollution degree

2

Ambient temperature during operating

-25 .. 75°C

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 50Hz

Connectable conductor cross section solid-core

1 .. 25mm²

Additional equipment possible

Over voltage category

3

Degree of protection (IP)

IP20