Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- ABB
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Follow current extinguishing capability
-kA
Voltage protection level (DC+ - DC-)
-kV
Specific energy (W/R)
-kJ/Ohm
Voltage protection level (DC+/DC- - PE)
-kV
System configuration DC
No
System configuration TN-S
Yes
System configuration TT
Yes
System configuration IT
No
Voltage protection level L-N
1.3kV
System configuration other
No
Voltage protection level L-PE
1.4kV
System configuration TN
No
System configuration TN-C-S
No
Nominal voltage AC
230V
Max. conductor cross section solid (solid, stranded)
35mm²
Lightning impulse current (10/350 µs)
12.5kA
System configuration TN-C
No
Construction size
4 modular spacing
Signalling at the device
None
Max. conductor cross section flexible (fine-strand)
25mm²
Voltage protection level N-PE
1.3kV
Number of poles
4
Exhausting
No
Max. continuous voltage AC
275V
Voltage protection level
0.8kV
Mounting method
DIN rail (top hat rail) 35 mm
Test class
Type 1 + 2
Remote signalling
No
Degree of protection (IP)
IP20
Energy-coordinated protection effect with regard to the terminal equipment
No
Integrated backup fuse
No
Max. overcurrent protection device, parallel connection (fuse)
-A
Overcurrent protected voltage tapping
No
Voltage switching spark gap technology
No
Max. overcurrent protection device, series connection (fuse)
-A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
2CTB815710R1900 | OVR T1-T2 3N 12.5-275s P QS

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- ABB
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Follow current extinguishing capability
-kA
Voltage protection level (DC+ - DC-)
-kV
Specific energy (W/R)
-kJ/Ohm
Voltage protection level (DC+/DC- - PE)
-kV
System configuration DC
System configuration TN-S
System configuration TT
System configuration IT
Voltage protection level L-N
1.3kV
System configuration other
Voltage protection level L-PE
1.4kV
System configuration TN
System configuration TN-C-S
Nominal voltage AC
230V
Max. conductor cross section solid (solid, stranded)
35mm²
Lightning impulse current (10/350 µs)
12.5kA
System configuration TN-C
Construction size
4 modular spacing
Signalling at the device
None
Max. conductor cross section flexible (fine-strand)
25mm²
Voltage protection level N-PE
1.3kV
Number of poles
4
Exhausting
Max. continuous voltage AC
275V
Voltage protection level
0.8kV
Mounting method
DIN rail (top hat rail) 35 mm
Test class
Type 1 + 2
Remote signalling
Degree of protection (IP)
IP20
Energy-coordinated protection effect with regard to the terminal equipment
Integrated backup fuse
Max. overcurrent protection device, parallel connection (fuse)
-A
Overcurrent protected voltage tapping
Voltage switching spark gap technology
Max. overcurrent protection device, series connection (fuse)
-A
From same serie
We use cookies to enhance your experience.