Main Product Image

2CCL562111E0164 | FS401E-C16/0.03 RCBO

Code: 1857826

ManufacturerABB
Catalog number2CCL562111E0164
EAN code7612270108589
Order only
Zagreb0 pcs
Zadar0 pcs

Sign in or create an account for lower prices and other benefits


WSP*
128,14 €
Neto128,14
RP160,17
pcs

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

No

Rated voltage

230V

Built-in depth

91mm

Width in number of modular spacings

1

Rated current

16A

Ambient temperature during operating

-25 - 40°C

Release characteristic

C

Number of protected poles

1

Connectable conductor cross section multi-wired

0.75 - 35mm²

Connectable conductor cross section solid-core

0.75 - 35mm²

Over voltage category

3

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Current limiting class

3

Pollution degree

2

Concurrently switching neutral conductor

No

Rated fault current

0.03A

Frequency

50/60 Hz

Leakage current type

A

With interlocking device

Yes

Surge current capacity

0.25kA

Anti-nuisance tripping version

No

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Power loss

2.7W

Flush-mounted installation

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCL562111E0164 | FS401E-C16/0.03 RCBO

Main Product Image

Code

1857826

Catalog number

2CCL562111E0164

Type

Earth leakage circuit breaker

Manufacturer

ABB

Serie

-

Neto WSP:

128,14

RP:160,17
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated voltage

230V

Built-in depth

91mm

Width in number of modular spacings

1

Rated current

16A

Ambient temperature during operating

-25 .. 40°C

Release characteristic

C

Number of protected poles

1

Connectable conductor cross section multi-wired

0.75 .. 35mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

3

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Current limiting class

3

Pollution degree

2

Concurrently switching neutral conductor

Rated fault current

0.03A

Frequency

50/60 Hz

Leakage current type

A

With interlocking device

Surge current capacity

0.25kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Power loss

2.7W

Flush-mounted installation

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.