Aleta.hr
Main Product Image

2CCL462110E0164 | FS451M-C16/0.03 RCBO

Code: 1857801

ManufacturerRAZNO
Catalog number2CCL462110E0164
Type
EAN code7612270108305

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

No

Rated current

16A

Width in number of modular spacings

2

Built-in depth

91mm

Rated voltage

240V

Release characteristic

C

Ambient temperature during operating

-25 - 40°C

Connectable conductor cross section multi-wired

0.75 - 35mm²

Connectable conductor cross section solid-core

0.75 - 35mm²

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of poles (total)

2

Current limiting class

3

Pollution degree

2

Concurrently switching neutral conductor

Yes

Over voltage category

3

Rated fault current

0.03A

Frequency

50/60 Hz

Leakage current type

A

Surge current capacity

0.25kA

With interlocking device

Yes

Anti-nuisance tripping version

No

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

3.2W

Flush-mounted installation

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCL462110E0164 | FS451M-C16/0.03 RCBO

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated current

16A

Width in number of modular spacings

2

Built-in depth

91mm

Rated voltage

240V

Release characteristic

C

Ambient temperature during operating

-25 .. 40°C

Connectable conductor cross section multi-wired

0.75 .. 35mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of poles (total)

2

Current limiting class

3

Pollution degree

2

Concurrently switching neutral conductor

Over voltage category

3

Rated fault current

0.03A

Frequency

50/60 Hz

Leakage current type

A

Surge current capacity

0.25kA

With interlocking device

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

3.2W

Flush-mounted installation