Technical specifications
Rated power, 460 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Number of auxiliary contacts as normally open contact
-
Number of auxiliary contacts as normally closed contact
-
Type of motor starter
Reversing starter
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
With short-circuit release
No
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 - 24V
Rated operation current at AC-3, 400 V
6.5A
Overload release current setting
0 - 0A
Rated operation power at AC-3, 400 V
3kW
Temperature compensated overload protection
Yes
Ambient temperature, upper operating limit
80°C
Release class
Other
Type of electrical connection of main circuit
Screw connection
Rated operation current Ie
9A
Rated operation power at AC-3, 230 V, 3-phase
1.50kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Yes
Number of command positions
16
External reset possible
No
Number of indicator lights
4
With fuse
No
Degree of protection (NEMA)
1
Suitable for emergency stop
No
Degree of protection (IP)
IP20
With transformer
No
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Supporting protocol for PROFIBUS
No
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Supporting protocol for PROFIsafe
No
Width
22.5mm
Height
99mm
Depth
114.5mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SAT144000R1011 | HF9-R ELECTRONIC COMPACT STAR

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- ABB
Technical specifications
Rated power, 460 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Number of auxiliary contacts as normally open contact
-
Number of auxiliary contacts as normally closed contact
-
Type of motor starter
Reversing starter
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
With short-circuit release
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Rated operation current at AC-3, 400 V
6.5A
Overload release current setting
0 .. 0A
Rated operation power at AC-3, 400 V
3kW
Temperature compensated overload protection
Ambient temperature, upper operating limit
80°C
Release class
Other
Type of electrical connection of main circuit
Screw connection
Rated operation current Ie
9A
Rated operation power at AC-3, 230 V, 3-phase
1.50kW
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Rail mounting possible
Number of command positions
16
External reset possible
Number of indicator lights
4
With fuse
Degree of protection (NEMA)
1
Suitable for emergency stop
Degree of protection (IP)
IP20
With transformer
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Supporting protocol for PROFIsafe
Width
22.5mm
Height
99mm
Depth
114.5mm
From same serie
We use cookies to enhance your experience.