Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- ABB
Technical specifications
Rated power, 460 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Number of auxiliary contacts as normally open contact
-
Number of auxiliary contacts as normally closed contact
-
With short-circuit release
No
Rated operation power at AC-3, 400 V
3kW
Rated control supply voltage Us at DC
24 - 24V
Rated operation current Ie
9A
Release class
CLASS 10 A
Rated operation current at AC-3, 400 V
6.5A
Rated operation power at AC-3, 230 V, 3-phase
1.50kW
Type of motor starter
Direct online starter (DOL)
Temperature compensated overload protection
Yes
Rated control supply voltage Us at AC 50HZ
0 - 0V
Overload release current setting
1.5 - 9.0A
Voltage type for actuating
DC
Rated control supply voltage Us at AC 60HZ
0 - 0V
Ambient temperature, upper operating limit
80°C
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
No
Rail mounting possible
Yes
Number of command positions
16
Suitable for emergency stop
No
Supporting protocol for PROFIBUS
No
Degree of protection (IP)
IP20
External reset possible
Yes
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Degree of protection (NEMA)
1
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Number of indicator lights
4
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for other bus systems
No
Width
22.5mm
Supporting protocol for AS-Interface Safety at Work
No
With fuse
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SUCONET
No
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for INTERBUS
No
Supporting protocol for TCP/IP
No
Supporting protocol for SafetyBUS p
No
Height
99mm
Depth
114.5mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SAT143000R1011 | HF9-DOLE ELECTRONIC COMPACT S

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- ABB
Technical specifications
Rated power, 460 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Number of auxiliary contacts as normally open contact
-
Number of auxiliary contacts as normally closed contact
-
With short-circuit release
Rated operation power at AC-3, 400 V
3kW
Rated control supply voltage Us at DC
24 .. 24V
Rated operation current Ie
9A
Release class
CLASS 10 A
Rated operation current at AC-3, 400 V
6.5A
Rated operation power at AC-3, 230 V, 3-phase
1.50kW
Type of motor starter
Direct online starter (DOL)
Temperature compensated overload protection
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Overload release current setting
1.5 .. 9.0A
Voltage type for actuating
DC
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Ambient temperature, upper operating limit
80°C
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
Rail mounting possible
Number of command positions
16
Suitable for emergency stop
Supporting protocol for PROFIBUS
Degree of protection (IP)
IP20
External reset possible
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Degree of protection (NEMA)
1
Supporting protocol for ASI
Supporting protocol for CAN
Number of indicator lights
4
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for Modbus
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for other bus systems
Width
22.5mm
Supporting protocol for AS-Interface Safety at Work
With fuse
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for SafetyBUS p
Height
99mm
Depth
114.5mm
From same serie
We use cookies to enhance your experience.