Aleta.hr
Main Product Image

1SAT126000R1011 | HF2.4-ROLE ELECTRONIC COMPACT

Code: 1856730

ManufacturerRAZNO
Catalog number1SAT126000R1011
Type
EAN code4013614515521

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

-

With short-circuit release

No

Type of motor starter

Reversing starter

Rated control supply voltage Us at DC

24 - 24V

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated control supply voltage Us at AC 50HZ

0 - 0V

Ambient temperature, upper operating limit

80°C

Temperature compensated overload protection

Yes

Release class

CLASS 10 A

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Voltage type for actuating

DC

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

No

Rated operation current Ie

2.4A

Number of indicator lights

4

Degree of protection (NEMA)

1

Supporting protocol for PROFIBUS

No

Overload release current setting

0.18 - 2.4A

Type of electrical connection of main circuit

Screw connection

Rated operation current at AC-3, 400 V

2.4A

Supporting protocol for TCP/IP

No

Degree of protection (IP)

IP20

Rated operation power at AC-3, 400 V

0.75kW

Number of command positions

16

Rail mounting possible

Yes

With fuse

No

External reset possible

Yes

Suitable for emergency stop

No

Supporting protocol for CAN

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for PROFINET IO

No

Height

99mm

Supporting protocol for Foundation Fieldbus

No

Width

22.5mm

Supporting protocol for INTERBUS-Safety

No

Depth

114.5mm

Supporting protocol for PROFINET CBA

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for DeviceNet

No

Supporting protocol for Data-Highway

No

Supporting protocol for PROFIsafe

No

Supporting protocol for LON

No

Supporting protocol for SUCONET

No

Supporting protocol for SERCOS

No

Supporting protocol for Modbus

No

Supporting protocol for other bus systems

No

Supporting protocol for AS-Interface Safety at Work

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SAT126000R1011 | HF2.4-ROLE ELECTRONIC COMPACT

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

-

With short-circuit release

Type of motor starter

Reversing starter

Rated control supply voltage Us at DC

24 .. 24V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Ambient temperature, upper operating limit

80°C

Temperature compensated overload protection

Release class

CLASS 10 A

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Voltage type for actuating

DC

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

Rated operation current Ie

2.4A

Number of indicator lights

4

Degree of protection (NEMA)

1

Supporting protocol for PROFIBUS

Overload release current setting

0.18 .. 2.4A

Type of electrical connection of main circuit

Screw connection

Rated operation current at AC-3, 400 V

2.4A

Supporting protocol for TCP/IP

Degree of protection (IP)

IP20

Rated operation power at AC-3, 400 V

0.75kW

Number of command positions

16

Rail mounting possible

With fuse

External reset possible

Suitable for emergency stop

Supporting protocol for CAN

Supporting protocol for DeviceNet Safety

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET IO

Height

99mm

Supporting protocol for Foundation Fieldbus

Width

22.5mm

Supporting protocol for INTERBUS-Safety

Depth

114.5mm

Supporting protocol for PROFINET CBA

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for PROFIsafe

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Supporting protocol for Modbus

Supporting protocol for other bus systems

Supporting protocol for AS-Interface Safety at Work

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.