Aleta.hr
Main Product Image

1SAT122000R1011 | HF2.4-DOL ELECTRONIC COMPACT

Code: 1856727

ManufacturerRAZNO
Catalog number1SAT122000R1011
Type
EAN code4013614515583

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

-

Type of motor starter

Direct online starter (DOL)

With short-circuit release

No

Rated control supply voltage Us at AC 50HZ

0 - 0V

Rated control supply voltage Us at DC

24 - 24V

Rated control supply voltage Us at AC 60HZ

0 - 0V

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated operation power at AC-3, 400 V

0.75kW

Rated operation current Ie

2.4A

Rated operation current at AC-3, 400 V

2.4A

Overload release current setting

0.18 - 2.4A

Temperature compensated overload protection

Yes

Release class

CLASS 10 A

Ambient temperature, upper operating limit

80°C

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for Data-Highway

No

Supporting protocol for TCP/IP

No

Supporting protocol for DeviceNet

No

Supporting protocol for SUCONET

No

Supporting protocol for INTERBUS

No

Supporting protocol for CAN

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for PROFINET IO

No

Supporting protocol for Modbus

No

Supporting protocol for ASI

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for LON

No

Rail mounting possible

Yes

Supporting protocol for EtherNet/IP

No

Supporting protocol for SERCOS

No

With transformer

No

Number of command positions

16

Number of indicator lights

4

With fuse

No

Degree of protection (IP)

IP20

Suitable for emergency stop

No

Supporting protocol for PROFIBUS

No

External reset possible

Yes

Degree of protection (NEMA)

1

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for AS-Interface Safety at Work

No

Height

99mm

Supporting protocol for DeviceNet Safety

No

Depth

114.5mm

Width

22.5mm

Supporting protocol for other bus systems

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SAT122000R1011 | HF2.4-DOL ELECTRONIC COMPACT

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • ABB

Technical specifications

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Number of auxiliary contacts as normally open contact

-

Number of auxiliary contacts as normally closed contact

-

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Rated control supply voltage Us at DC

24 .. 24V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Voltage type for actuating

DC

Rated operation power at AC-3, 230 V, 3-phase

0.37kW

Rated operation power at AC-3, 400 V

0.75kW

Rated operation current Ie

2.4A

Rated operation current at AC-3, 400 V

2.4A

Overload release current setting

0.18 .. 2.4A

Temperature compensated overload protection

Release class

CLASS 10 A

Ambient temperature, upper operating limit

80°C

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Supporting protocol for Data-Highway

Supporting protocol for TCP/IP

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Supporting protocol for CAN

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for INTERBUS-Safety

Supporting protocol for LON

Rail mounting possible

Supporting protocol for EtherNet/IP

Supporting protocol for SERCOS

With transformer

Number of command positions

16

Number of indicator lights

4

With fuse

Degree of protection (IP)

IP20

Suitable for emergency stop

Supporting protocol for PROFIBUS

External reset possible

Degree of protection (NEMA)

1

Supporting protocol for Foundation Fieldbus

Supporting protocol for AS-Interface Safety at Work

Height

99mm

Supporting protocol for DeviceNet Safety

Depth

114.5mm

Width

22.5mm

Supporting protocol for other bus systems

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.