Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- ABB
Technical specifications
Rated power, 460 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Number of auxiliary contacts as normally open contact
-
Number of auxiliary contacts as normally closed contact
-
Type of motor starter
Reversing starter
With short-circuit release
No
Rated control supply voltage Us at DC
24 - 24V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated operation power at AC-3, 400 V
0.18kW
Voltage type for actuating
DC
Ambient temperature, upper operating limit
80°C
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Rated operation current Ie
0.6A
Overload release current setting
0.075 - 0.600A
Rated operation current at AC-3, 400 V
0.6A
Rated control supply voltage Us at AC 50HZ
0 - 0V
Temperature compensated overload protection
Yes
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Release class
CLASS 10 A
With transformer
No
Number of command positions
16
Type of electrical connection of main circuit
Screw connection
Rail mounting possible
Yes
Suitable for emergency stop
No
Number of indicator lights
4
External reset possible
Yes
With fuse
No
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Supporting protocol for PROFIBUS
No
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
No
Supporting protocol for LON
No
Degree of protection (NEMA)
1
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Degree of protection (IP)
IP20
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for other bus systems
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Width
22.5mm
Depth
114.5mm
Supporting protocol for EtherNet/IP
No
Height
99mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SAT116000R1011 | HF0.6-ROLE ELECTRONIC COMPACT

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- ABB
Technical specifications
Rated power, 460 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Number of auxiliary contacts as normally open contact
-
Number of auxiliary contacts as normally closed contact
-
Type of motor starter
Reversing starter
With short-circuit release
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated operation power at AC-3, 400 V
0.18kW
Voltage type for actuating
DC
Ambient temperature, upper operating limit
80°C
Rated operation power at AC-3, 230 V, 3-phase
0.09kW
Rated operation current Ie
0.6A
Overload release current setting
0.075 .. 0.600A
Rated operation current at AC-3, 400 V
0.6A
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Temperature compensated overload protection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Release class
CLASS 10 A
With transformer
Number of command positions
16
Type of electrical connection of main circuit
Screw connection
Rail mounting possible
Suitable for emergency stop
Number of indicator lights
4
External reset possible
With fuse
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for LON
Degree of protection (NEMA)
1
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Degree of protection (IP)
IP20
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Width
22.5mm
Depth
114.5mm
Supporting protocol for EtherNet/IP
Height
99mm
From same serie