Technical specifications
Number of poles
3
Type of control element
Door coupling rotary drive
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
32A
Motor drive optional
No
Device construction
Complete device in housing
Type of electrical connection of main circuit
Screw connection
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Yes
Suitable for intermediate mounting
No
Suitable for distribution board installation
No
Rated operation power at AC-3, 400 V
-kW
Degree of protection (IP), front side
IP65
Max. rated operation voltage Ue AC
800V
Conditioned rated short-circuit current Iq
50kA
Rated operating voltage
400 - 690V
Suitable for front mounting 4-hole
Yes
Suitable for front mounting centre
No
Voltage release optional
No
Version as maintenance-/service switch
Yes
Switching power at 400 V
15kW
Interlockable
Yes
Rated permanent current at AC-23, 400 V
32A
Rated operation power at AC-23, 400 V
15kW
Colour control element
Red
Version as main switch
Yes
Version as reversing switch
No
Version as safety switch
Yes
Rated short-time withstand current lcw
1.26kA
Version as emergency stop installation
Yes
Rated permanent current at AC-21, 400 V
32A
Number of switches
1
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
Code: 1853070
30325303 | ENCLOSED LOAD BREAK SWITCH SIRCO M 32

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SOCOMEC
Technical specifications
Number of poles
3
Type of control element
Door coupling rotary drive
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
32A
Motor drive optional
Device construction
Complete device in housing
Type of electrical connection of main circuit
Screw connection
Motor drive integrated
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Suitable for intermediate mounting
Suitable for distribution board installation
Rated operation power at AC-3, 400 V
-kW
Degree of protection (IP), front side
IP65
Max. rated operation voltage Ue AC
800V
Conditioned rated short-circuit current Iq
50kA
Rated operating voltage
400 .. 690V
Suitable for front mounting 4-hole
Suitable for front mounting centre
Voltage release optional
Version as maintenance-/service switch
Switching power at 400 V
15kW
Interlockable
Rated permanent current at AC-23, 400 V
32A
Rated operation power at AC-23, 400 V
15kW
Colour control element
Red
Version as main switch
Version as reversing switch
Version as safety switch
Rated short-time withstand current lcw
1.26kA
Version as emergency stop installation
Rated permanent current at AC-21, 400 V
32A
Number of switches
1