![Main Product Image](https://assets.aleta.hr/415x415/d81614c2-092c-40d0-804b-c952bef0cb3b.webp)
![Main Product Image](https://assets.aleta.hr/415x415/d81614c2-092c-40d0-804b-c952bef0cb3b.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains frequency
50/60 Hz
Mains voltage
500 - 690V
Max. output at quadratic load at rated output voltage
5.5kW
Max. output frequency
30000Hz
Number of phases input
3
Nominal output current I2N
7.2A
Relative symmetric net frequency tolerance
5%
Max. output voltage
30V
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Number of analogue inputs
3
Supporting protocol for TCP/IP
Yes
Number of digital outputs
1
Application in industrial area permitted
No
Number of digital inputs
8
Application in domestic- and commercial area permitted
No
Supporting protocol for Modbus
Yes
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for ASI
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
With control element
Yes
Supporting protocol for KNX
No
Supporting protocol for PROFINET CBA
No
Max. output at linear load at rated output voltage
5.5kW
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for LON
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Foundation Fieldbus
No
Number of phases output
2
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Supporting protocol for INTERBUS-Safety
No
Number of interfaces PROFINET
0
Supporting protocol for other bus systems
No
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
2
Number of HW-interfaces other
0
With optical interface
No
Integrated breaking resistance
No
With PC connection
No
Number of HW-interfaces RS-232
0
Type of converter
U converter
4-quadrant operation possible
No
Degree of protection (IP)
IP00
Height
420mm
Width
246mm
Depth
242mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV930U55Y6
![Main Product Image](https://assets.aleta.hr/300x300/1427ba02-0a6e-4da2-9425-66397b157566_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains frequency
50/60 Hz
Mains voltage
500 .. 690V
Max. output at quadratic load at rated output voltage
5.5kW
Max. output frequency
30000Hz
Number of phases input
3
Nominal output current I2N
7.2A
Relative symmetric net frequency tolerance
5%
Max. output voltage
30V
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Number of analogue inputs
3
Supporting protocol for TCP/IP
Number of digital outputs
1
Application in industrial area permitted
Number of digital inputs
8
Application in domestic- and commercial area permitted
Supporting protocol for Modbus
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for ASI
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
With control element
Supporting protocol for KNX
Supporting protocol for PROFINET CBA
Max. output at linear load at rated output voltage
5.5kW
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for LON
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Number of phases output
2
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Supporting protocol for INTERBUS-Safety
Number of interfaces PROFINET
0
Supporting protocol for other bus systems
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
2
Number of HW-interfaces other
0
With optical interface
Integrated breaking resistance
With PC connection
Number of HW-interfaces RS-232
0
Type of converter
U converter
4-quadrant operation possible
Degree of protection (IP)
IP00
Height
420mm
Width
246mm
Depth
242mm
From same serie