ATV930U22Y6

Code: 1852616

ManufacturerRAZNO
Catalog numberATV930U22Y6
Type
EAN code3606481325242

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for Data-Highway

No

Supporting protocol for SUCONET

No

Supporting protocol for INTERBUS

No

Number of HW-interfaces parallel

0

Mains frequency

50/60 Hz

Number of HW-interfaces USB

0

Supporting protocol for SERCOS

No

Number of phases output

2

Supporting protocol for DeviceNet

Yes

Relative symmetric net frequency tolerance

5%

Relative symmetric net voltage tolerance

10%

Supporting protocol for SafetyBUS p

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFINET CBA

No

Mains voltage

500 - 690V

Supporting protocol for PROFIsafe

No

Max. output at linear load at rated output voltage

2.2kW

Supporting protocol for Modbus

Yes

Number of HW-interfaces RS-232

0

Number of analogue outputs

2

Max. output frequency

30000Hz

Nominal output current I2N

3.1A

Supporting protocol for PROFINET IO

No

Supporting protocol for TCP/IP

Yes

With control element

Yes

Number of phases input

3

Number of digital outputs

1

Supporting protocol for PROFIBUS

Yes

Supporting protocol for Foundation Fieldbus

No

Number of HW-interfaces RS-485

2

Supporting protocol for EtherNet/IP

Yes

Supporting protocol for LON

No

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for CAN

No

Number of digital inputs

8

Number of HW-interfaces RS-422

0

Number of interfaces PROFINET

0

Number of analogue inputs

3

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Number of HW-interfaces other

0

Number of HW-interfaces industrial Ethernet

2

Application in industrial area permitted

No

Supporting protocol for ASI

No

Max. output voltage

30V

Supporting protocol for KNX

No

Application in domestic- and commercial area permitted

No

Supporting protocol for BACnet

No

Supporting protocol for other bus systems

No

Number of HW-interfaces serial TTY

0

With optical interface

No

With PC connection

No

Integrated breaking resistance

No

4-quadrant operation possible

No

Degree of protection (IP)

IP00

Type of converter

U converter

Height

420mm

Depth

242mm

Width

246mm


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

ATV930U22Y6

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • SCHNEIDER

Technical specifications

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

Supporting protocol for INTERBUS

Number of HW-interfaces parallel

0

Mains frequency

50/60 Hz

Number of HW-interfaces USB

0

Supporting protocol for SERCOS

Number of phases output

2

Supporting protocol for DeviceNet

Relative symmetric net frequency tolerance

5%

Relative symmetric net voltage tolerance

10%

Supporting protocol for SafetyBUS p

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFINET CBA

Mains voltage

500 .. 690V

Supporting protocol for PROFIsafe

Max. output at linear load at rated output voltage

2.2kW

Supporting protocol for Modbus

Number of HW-interfaces RS-232

0

Number of analogue outputs

2

Max. output frequency

30000Hz

Nominal output current I2N

3.1A

Supporting protocol for PROFINET IO

Supporting protocol for TCP/IP

With control element

Number of phases input

3

Number of digital outputs

1

Supporting protocol for PROFIBUS

Supporting protocol for Foundation Fieldbus

Number of HW-interfaces RS-485

2

Supporting protocol for EtherNet/IP

Supporting protocol for LON

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for CAN

Number of digital inputs

8

Number of HW-interfaces RS-422

0

Number of interfaces PROFINET

0

Number of analogue inputs

3

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Number of HW-interfaces other

0

Number of HW-interfaces industrial Ethernet

2

Application in industrial area permitted

Supporting protocol for ASI

Max. output voltage

30V

Supporting protocol for KNX

Application in domestic- and commercial area permitted

Supporting protocol for BACnet

Supporting protocol for other bus systems

Number of HW-interfaces serial TTY

0

With optical interface

With PC connection

Integrated breaking resistance

4-quadrant operation possible

Degree of protection (IP)

IP00

Type of converter

U converter

Height

420mm

Depth

242mm

Width

246mm

From same serie