Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
500 - 690V
Mains frequency
50/60 Hz
Nominal output current I2N
66A
Number of phases input
3
Relative symmetric net frequency tolerance
5%
Supporting protocol for CAN
No
Application in industrial area permitted
No
Number of digital outputs
1
Number of analogue inputs
3
Max. output voltage
30V
Number of phases output
2
Supporting protocol for Modbus
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for KNX
No
Max. output frequency
30000Hz
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Max. output at linear load at rated output voltage
55kW
Relative symmetric net voltage tolerance
10%
Supporting protocol for Data-Highway
No
With control element
Yes
Application in domestic- and commercial area permitted
No
Max. output at quadratic load at rated output voltage
55kW
Supporting protocol for TCP/IP
Yes
Number of digital inputs
8
Number of analogue outputs
2
Supporting protocol for PROFIBUS
Yes
Supporting protocol for LON
No
With optical interface
Yes
With PC connection
No
Integrated breaking resistance
No
Degree of protection (IP)
IP00
4-quadrant operation possible
No
Type of converter
U converter
Width
331mm
Depth
297mm
Height
630mm
Supporting protocol for SERCOS
No
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces industrial Ethernet
2
Supporting protocol for PROFINET CBA
No
Number of HW-interfaces RS-422
0
Supporting protocol for Foundation Fieldbus
No
Number of HW-interfaces RS-485
2
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for other bus systems
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for BACnet
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV930D55Y6
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
500 .. 690V
Mains frequency
50/60 Hz
Nominal output current I2N
66A
Number of phases input
3
Relative symmetric net frequency tolerance
5%
Supporting protocol for CAN
Application in industrial area permitted
Number of digital outputs
1
Number of analogue inputs
3
Max. output voltage
30V
Number of phases output
2
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for KNX
Max. output frequency
30000Hz
Supporting protocol for INTERBUS
Supporting protocol for ASI
Max. output at linear load at rated output voltage
55kW
Relative symmetric net voltage tolerance
10%
Supporting protocol for Data-Highway
With control element
Application in domestic- and commercial area permitted
Max. output at quadratic load at rated output voltage
55kW
Supporting protocol for TCP/IP
Number of digital inputs
8
Number of analogue outputs
2
Supporting protocol for PROFIBUS
Supporting protocol for LON
With optical interface
With PC connection
Integrated breaking resistance
Degree of protection (IP)
IP00
4-quadrant operation possible
Type of converter
U converter
Width
331mm
Depth
297mm
Height
630mm
Supporting protocol for SERCOS
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces industrial Ethernet
2
Supporting protocol for PROFINET CBA
Number of HW-interfaces RS-422
0
Supporting protocol for Foundation Fieldbus
Number of HW-interfaces RS-485
2
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Supporting protocol for SafetyBUS p
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Supporting protocol for EtherNet/IP
Supporting protocol for other bus systems
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for BACnet
From same serie
We use cookies to enhance your experience.