Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
2
Mains voltage
500 - 690V
Max. output voltage
690V
Mains frequency
50/60 Hz
Number of phases input
3
Nominal output current I2N
66A
Max. output frequency
500Hz
Max. output at quadratic load at rated output voltage
55kW
Relative symmetric net voltage tolerance
10%
Max. output at linear load at rated output voltage
55kW
Relative symmetric net frequency tolerance
5%
Number of analogue outputs
2
Number of analogue inputs
3
Number of digital inputs
6
Number of digital outputs
0
Supporting protocol for TCP/IP
Yes
With control element
No
Application in industrial area permitted
No
Application in domestic- and commercial area permitted
No
With optical interface
Yes
With PC connection
No
4-quadrant operation possible
No
Integrated breaking resistance
No
Type of converter
U converter
Degree of protection (IP)
IP21
Height
630mm
Depth
297mm
Width
331mm
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for KNX
No
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for BACnet
No
Number of interfaces PROFINET
0
Supporting protocol for other bus systems
No
Number of HW-interfaces RS-485
2
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV630D55Y6
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
2
Mains voltage
500 .. 690V
Max. output voltage
690V
Mains frequency
50/60 Hz
Number of phases input
3
Nominal output current I2N
66A
Max. output frequency
500Hz
Max. output at quadratic load at rated output voltage
55kW
Relative symmetric net voltage tolerance
10%
Max. output at linear load at rated output voltage
55kW
Relative symmetric net frequency tolerance
5%
Number of analogue outputs
2
Number of analogue inputs
3
Number of digital inputs
6
Number of digital outputs
0
Supporting protocol for TCP/IP
With control element
Application in industrial area permitted
Application in domestic- and commercial area permitted
With optical interface
With PC connection
4-quadrant operation possible
Integrated breaking resistance
Type of converter
U converter
Degree of protection (IP)
IP21
Height
630mm
Depth
297mm
Width
331mm
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for KNX
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for BACnet
Number of interfaces PROFINET
0
Supporting protocol for other bus systems
Number of HW-interfaces RS-485
2
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
0
Number of HW-interfaces USB
0
From same serie
We use cookies to enhance your experience.