Technical specifications
Mains frequency
50/60 Hz
Max. output voltage
500V
Max. output frequency
599Hz
Relative symmetric net voltage tolerance
10%
Mains voltage
380 - 500V
Max. output at linear load at rated output voltage
0.55kW
Relative symmetric net frequency tolerance
5%
Nominal output current I2N
1.9A
Supporting protocol for TCP/IP
Yes
Max. output at quadratic load at rated output voltage
0.55kW
Application in domestic- and commercial area permitted
No
Application in industrial area permitted
Yes
With control element
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
Yes
Supporting protocol for ASI
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET CBA
No
Number of digital outputs
3
Number of analogue inputs
3
Supporting protocol for SafetyBUS p
No
Supporting protocol for CAN
Yes
Supporting protocol for BACnet
No
Supporting protocol for PROFIsafe
No
Number of phases output
3
Number of phases input
3
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Number of analogue outputs
1
Number of digital inputs
7
Supporting protocol for KNX
No
Supporting protocol for Data-Highway
No
Supporting protocol for LON
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for DeviceNet
Yes
With optical interface
No
4-quadrant operation possible
Yes
With PC connection
Yes
Degree of protection (IP)
IP65
Integrated breaking resistance
Yes
Type of converter
U converter
Degree of protection (NEMA)
12
Height
340mm
Depth
200mm
Width
250mm
Number of HW-interfaces RS-232
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
Yes
Number of interfaces PROFINET
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
1
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV320U06N4WS
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains frequency
50/60 Hz
Max. output voltage
500V
Max. output frequency
599Hz
Relative symmetric net voltage tolerance
10%
Mains voltage
380 .. 500V
Max. output at linear load at rated output voltage
0.55kW
Relative symmetric net frequency tolerance
5%
Nominal output current I2N
1.9A
Supporting protocol for TCP/IP
Max. output at quadratic load at rated output voltage
0.55kW
Application in domestic- and commercial area permitted
Application in industrial area permitted
With control element
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for SUCONET
Supporting protocol for PROFINET CBA
Number of digital outputs
3
Number of analogue inputs
3
Supporting protocol for SafetyBUS p
Supporting protocol for CAN
Supporting protocol for BACnet
Supporting protocol for PROFIsafe
Number of phases output
3
Number of phases input
3
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Number of analogue outputs
1
Number of digital inputs
7
Supporting protocol for KNX
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet
With optical interface
4-quadrant operation possible
With PC connection
Degree of protection (IP)
IP65
Integrated breaking resistance
Type of converter
U converter
Degree of protection (NEMA)
12
Height
340mm
Depth
200mm
Width
250mm
Number of HW-interfaces RS-232
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Supporting protocol for other bus systems
Number of interfaces PROFINET
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
1