Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

Yes

System configuration IT

No

System configuration TN

No

System configuration TN-C

No

System configuration TN-C-S

No

System configuration TN-S

No

System configuration TT

No

System configuration other

No

Number of poles

-

Lightning impulse current (10/350 µs)

-kA

Max. continuous voltage AC

-V

Max. continuous voltage DC

1500V

Nominal voltage DC

-V

Nominal voltage AC

-V

Max. PV-voltage

-V

Voltage protection level

4.5kV

Voltage protection level L-N

-kV

Voltage protection level L-PE

-kV

Voltage protection level N-PE

-kV

Voltage protection level (DC+ - DC-)

-kV

Follow current extinguishing capability

-kA

Specific energy (W/R)

-kJ/Ohm

Max. overcurrent protection device, parallel connection (fuse)

-A

Voltage protection level (DC+/DC- - PE)

-kV

Max. overcurrent protection device, series connection (fuse)

-A

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

4 modular spacing

Max. conductor cross section solid (solid, stranded)

35mm²

Remote signalling

No

Max. conductor cross section flexible (fine-strand)

35mm²

Signalling at the device

Optic

Energy-coordinated protection effect with regard to the terminal equipment

No

Voltage switching spark gap technology

No

Integrated backup fuse

No

Overcurrent protected voltage tapping

No

Degree of protection (IP)

IP20


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

5094210 | V-PV-T2-1500

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

System configuration IT

System configuration TN

System configuration TN-C

System configuration TN-C-S

System configuration TN-S

System configuration TT

System configuration other

Number of poles

-

Lightning impulse current (10/350 µs)

-kA

Max. continuous voltage AC

-V

Max. continuous voltage DC

1500V

Nominal voltage DC

-V

Nominal voltage AC

-V

Max. PV-voltage

-V

Voltage protection level

4.5kV

Voltage protection level L-N

-kV

Voltage protection level L-PE

-kV

Voltage protection level N-PE

-kV

Voltage protection level (DC+ - DC-)

-kV

Follow current extinguishing capability

-kA

Specific energy (W/R)

-kJ/Ohm

Max. overcurrent protection device, parallel connection (fuse)

-A

Voltage protection level (DC+/DC- - PE)

-kV

Max. overcurrent protection device, series connection (fuse)

-A

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

4 modular spacing

Max. conductor cross section solid (solid, stranded)

35mm²

Remote signalling

Max. conductor cross section flexible (fine-strand)

35mm²

Signalling at the device

Optic

Energy-coordinated protection effect with regard to the terminal equipment

Voltage switching spark gap technology

Integrated backup fuse

Overcurrent protected voltage tapping

Degree of protection (IP)

IP20

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.