Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Rated control supply voltage Us at DC
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
No
With short-circuit release
No
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
AC
Rated control supply voltage Us at AC 60HZ
380 - 400V
Rated control supply voltage Us at AC 50HZ
380 - 400V
Rated operation power at AC-3, 400 V
2.2kW
Rated operation current Ie
6A
Rated operation power at AC-3, 230 V, 3-phase
1.1kW
Rated power, 460 V, 60 Hz, 3-phase
3kW
Number of auxiliary contacts as normally open contact
0
Rated operation current at AC-3, 400 V
6A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Ambient temperature, upper operating limit
40°C
Suitable for emergency stop
Yes
Number of command positions
4
With transformer
No
Rail mounting possible
No
External reset possible
No
Number of indicator lights
0
Degree of protection (IP)
IP55
With fuse
No
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Supporting protocol for PROFIBUS
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for other bus systems
No
Supporting protocol for PROFIsafe
No
Height
165mm
Width
175mm
Supporting protocol for SafetyBUS p
No
Depth
177mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LG7K06Q7

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Rated control supply voltage Us at DC
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
Temperature compensated overload protection
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Voltage type for actuating
AC
Rated control supply voltage Us at AC 60HZ
380 .. 400V
Rated control supply voltage Us at AC 50HZ
380 .. 400V
Rated operation power at AC-3, 400 V
2.2kW
Rated operation current Ie
6A
Rated operation power at AC-3, 230 V, 3-phase
1.1kW
Rated power, 460 V, 60 Hz, 3-phase
3kW
Number of auxiliary contacts as normally open contact
0
Rated operation current at AC-3, 400 V
6A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Ambient temperature, upper operating limit
40°C
Suitable for emergency stop
Number of command positions
4
With transformer
Rail mounting possible
External reset possible
Number of indicator lights
0
Degree of protection (IP)
IP55
With fuse
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for other bus systems
Supporting protocol for PROFIsafe
Height
165mm
Width
175mm
Supporting protocol for SafetyBUS p
Depth
177mm
From same serie
We use cookies to enhance your experience.