Aleta.hr
Main Product Image

LG7K06Q7

Code: 1796026

ManufacturerRAZNO
Catalog numberLG7K06Q7
Type
EAN code3389110604252

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- - -A

Rated control supply voltage Us at DC

- - -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

No

With short-circuit release

No

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

380 - 400V

Rated control supply voltage Us at AC 50HZ

380 - 400V

Rated operation power at AC-3, 400 V

2.2kW

Rated operation current Ie

6A

Rated operation power at AC-3, 230 V, 3-phase

1.1kW

Rated power, 460 V, 60 Hz, 3-phase

3kW

Number of auxiliary contacts as normally open contact

0

Rated operation current at AC-3, 400 V

6A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Ambient temperature, upper operating limit

40°C

Suitable for emergency stop

Yes

Number of command positions

4

With transformer

No

Rail mounting possible

No

External reset possible

No

Number of indicator lights

0

Degree of protection (IP)

IP55

With fuse

No

Supporting protocol for TCP/IP

No

Supporting protocol for CAN

No

Supporting protocol for PROFIBUS

No

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for Data-Highway

No

Supporting protocol for Modbus

No

Supporting protocol for SUCONET

No

Supporting protocol for DeviceNet

No

Supporting protocol for LON

No

Supporting protocol for PROFINET IO

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SERCOS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for other bus systems

No

Supporting protocol for PROFIsafe

No

Height

165mm

Width

175mm

Supporting protocol for SafetyBUS p

No

Depth

177mm


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

LG7K06Q7

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/Motor starter combination
  • 1 KOM
  • SCHNEIDER

Technical specifications

Overload release current setting

- .. -A

Rated control supply voltage Us at DC

- .. -V

Rated conditional short-circuit current, type 2, 400 V

-A

Rated conditional short-circuit current, type 1, 480 Y/277 V

-A

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 1, 600 Y/347 V

-A

Rated conditional short-circuit current, type 2, 230 V

-A

Temperature compensated overload protection

With short-circuit release

Type of motor starter

Direct online starter (DOL)

Voltage type for actuating

AC

Rated control supply voltage Us at AC 60HZ

380 .. 400V

Rated control supply voltage Us at AC 50HZ

380 .. 400V

Rated operation power at AC-3, 400 V

2.2kW

Rated operation current Ie

6A

Rated operation power at AC-3, 230 V, 3-phase

1.1kW

Rated power, 460 V, 60 Hz, 3-phase

3kW

Number of auxiliary contacts as normally open contact

0

Rated operation current at AC-3, 400 V

6A

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Screw connection

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Ambient temperature, upper operating limit

40°C

Suitable for emergency stop

Number of command positions

4

With transformer

Rail mounting possible

External reset possible

Number of indicator lights

0

Degree of protection (IP)

IP55

With fuse

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for Modbus

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for INTERBUS-Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for other bus systems

Supporting protocol for PROFIsafe

Height

165mm

Width

175mm

Supporting protocol for SafetyBUS p

Depth

177mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.