411580 | TX3 FID 2P 40A A 500MA

Code: 1778989

ManufacturerLegrand
Catalog number411521
EAN code3414970352941
Order only
Zagreb0 pcs
Zadar0 pcs

Sign in or create an account for lower prices and other benefits


WSP*
49,63 €
Neto49,63
RP62,04
pcs

Details

  • Circuit breakers and fuses
  • Residual current circuit breaker (RCCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Mounting method

DIN rail

Number of poles

2

Built-in depth

44mm

Rated current

40A

Rated voltage

230V

Width in number of modular spacings

2

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section multi-wired

0.75 - 35mm²

Connectable conductor cross section solid-core

0.75 - 50mm²

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

250V

Additional equipment possible

Yes

Pollution degree

2

Frequency

50 Hz

Leakage current type

A

With interlocking device

Yes

Surge current capacity

0.25kA

Rated fault current

500mA

Short-circuit breaking capacity (Icw)

10kA

Selective protection

No

Short-time delayed tripping

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

411580 | TX3 FID 2P 40A A 500MA

Main Product Image

Code

1778989

Catalog number

411521

Type

Residual current circuit breaker (RCCB)

Manufacturer

Legrand

Serie

-

Neto WSP:

49,63

RP:62,04
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Circuit breakers and fuses
  • Residual current circuit breaker (RCCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Mounting method

DIN rail

Number of poles

2

Built-in depth

44mm

Rated current

40A

Rated voltage

230V

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 35mm²

Connectable conductor cross section solid-core

0.75 .. 50mm²

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

250V

Additional equipment possible

Pollution degree

2

Frequency

50 Hz

Leakage current type

A

With interlocking device

Surge current capacity

0.25kA

Rated fault current

500mA

Short-circuit breaking capacity (Icw)

10kA

Selective protection

Short-time delayed tripping