Aleta.hr
Main Product Image

411527 | FID DX3-ID 2P 80A AC 300MA

Code: 1778955

ManufacturerLegrand
Catalog number411735
EAN code3245064115278
Order only
Zagreb0 pcs
Zadar0 pcs

Sign in or create an account for lower prices and other benefits


WSP*
170,48 €
Neto170,48
RP213,10
pcs

Details

  • Circuit breakers and fuses
  • Residual current circuit breaker (RCCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Mounting method

DIN rail

Number of poles

2

Rated current

80A

Rated voltage

230V

Width in number of modular spacings

2

Built-in depth

44mm

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section multi-wired

0.75 - 35mm²

Connectable conductor cross section solid-core

0.75 - 50mm²

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

250V

Additional equipment possible

Yes

Pollution degree

2

Frequency

50 Hz

Leakage current type

AC

With interlocking device

Yes

Surge current capacity

0.25kA

Rated fault current

300mA

Short-circuit breaking capacity (Icw)

10kA

Selective protection

No

Short-time delayed tripping

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

411527 | FID DX3-ID 2P 80A AC 300MA

Main Product Image

Code

1778955

Catalog number

411735

Type

Residual current circuit breaker (RCCB)

Manufacturer

Legrand

Serie

-

Neto WSP:

170,48

RP:213,10
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Circuit breakers and fuses
  • Residual current circuit breaker (RCCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Mounting method

DIN rail

Number of poles

2

Rated current

80A

Rated voltage

230V

Width in number of modular spacings

2

Built-in depth

44mm

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0.75 .. 35mm²

Connectable conductor cross section solid-core

0.75 .. 50mm²

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

250V

Additional equipment possible

Pollution degree

2

Frequency

50 Hz

Leakage current type

AC

With interlocking device

Surge current capacity

0.25kA

Rated fault current

300mA

Short-circuit breaking capacity (Icw)

10kA

Selective protection

Short-time delayed tripping

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.