Aleta.hr
Main Product Image

409436 | DX3 AUTOM OSIG 1P D40 16KA

Code: 1778437

ManufacturerRAZNO
Catalog number409436
Type
EAN code3414970434098

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Built-in depth

44mm

Suitable for flush-mounted installation

Yes

Width in number of modular spacings

1

Rated current

40A

Rated voltage

230V

Release characteristic

D

Connectable conductor cross section multi-wired

1.5 - 25mm²

Number of protected poles

1

Connectable conductor cross section solid-core

1.5 - 35mm²

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of poles (total)

1

Rated insulation voltage Ui

500V

Current limiting class

-

Additional equipment possible

Yes

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Ambient temperature during operating

-25 - 70°C

Frequency

50 - 60Hz

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Over voltage category

-

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

409436 | DX3 AUTOM OSIG 1P D40 16KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Built-in depth

44mm

Suitable for flush-mounted installation

Width in number of modular spacings

1

Rated current

40A

Rated voltage

230V

Release characteristic

D

Connectable conductor cross section multi-wired

1.5 .. 25mm²

Number of protected poles

1

Connectable conductor cross section solid-core

1.5 .. 35mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of poles (total)

1

Rated insulation voltage Ui

500V

Current limiting class

-

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Ambient temperature during operating

-25 .. 70°C

Frequency

50 .. 60Hz

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Over voltage category

-

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.