Aleta.hr
Main Product Image

404186 | TX3 AUTOM OSIG 1P+N C10 10KA

Code: 1777960

ManufacturerRAZNO
Catalog number404186
Type
EAN code3414970393739

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Yes

Rated current

10A

Rated voltage

230V

Width in number of modular spacings

2

Built-in depth

44mm

Release characteristic

C

Ambient temperature during operating

- - -°C

Connectable conductor cross section multi-wired

- - -mm²

Connectable conductor cross section solid-core

- - -mm²

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

3

Additional equipment possible

Yes

Frequency

50 - 60Hz

Pollution degree

2

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

Yes

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

404186 | TX3 AUTOM OSIG 1P+N C10 10KA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 5 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated current

10A

Rated voltage

230V

Width in number of modular spacings

2

Built-in depth

44mm

Release characteristic

C

Ambient temperature during operating

- .. -°C

Connectable conductor cross section multi-wired

- .. -mm²

Connectable conductor cross section solid-core

- .. -mm²

Number of protected poles

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

3

Additional equipment possible

Frequency

50 .. 60Hz

Pollution degree

2

Over voltage category

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.