Degree of protection (IP)

IP20

Construction size

1 modular spacing

Number of conductors (without earthing)

-

Max. continuous voltage AC

440V

Signalling at the device

Optic

Max. continuous voltage DC

-V

Voltage protection level

1.8kV

Nominal voltage AC

400V

Voltage protection level L-N

-kV

Max. conductor cross section solid (solid, stranded)

-mm²

Max. conductor cross section flexible (fine-strand)

-mm²

Integrated backup fuse

No

Nominal voltage DC

-V

With remote signalling contact

No

Nominal discharge surge current (8/20)

15kA

Voltage protection level N-PE

-kV

System configuration TN

No

System configuration DC

No

System configuration TN-S

No

System configuration IT

No

System configuration other

Yes

System configuration TT

No

System configuration TN-C

No

System configuration TN-C-S

No

Max. PV-voltage

-V

Category type 2

Yes

Max. discharge surge current (8/20)

-kA

Short-circuit breaking capacity (Isccr)

-kA


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

003934 | ZAMJENSKI MODUL 40 KA

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • LEGRAND

Technical specifications

Degree of protection (IP)

IP20

Construction size

1 modular spacing

Number of conductors (without earthing)

-

Max. continuous voltage AC

440V

Signalling at the device

Optic

Max. continuous voltage DC

-V

Voltage protection level

1.8kV

Nominal voltage AC

400V

Voltage protection level L-N

-kV

Max. conductor cross section solid (solid, stranded)

-mm²

Max. conductor cross section flexible (fine-strand)

-mm²

Integrated backup fuse

Nominal voltage DC

-V

With remote signalling contact

Nominal discharge surge current (8/20)

15kA

Voltage protection level N-PE

-kV

System configuration TN

System configuration DC

System configuration TN-S

System configuration IT

System configuration other

System configuration TT

System configuration TN-C

System configuration TN-C-S

Max. PV-voltage

-V

Category type 2

Max. discharge surge current (8/20)

-kA

Short-circuit breaking capacity (Isccr)