Main Product Image

NCN150

Code: 1762763

ManufacturerHager
Catalog numberNCN150
EAN code3250614614675
Order only
Zagreb0 pcs
Zadar0 pcs

Sign in or create an account for lower prices and other benefits


WSP*
9,76 €
Neto9,76
RP12,20
pcs

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Yes

Width in number of modular spacings

1

Rated current

50A

Rated voltage

400V

Built-in depth

70mm

Release characteristic

C

Number of protected poles

1

Over voltage category

3

Number of poles (total)

1

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible

Yes

Frequency

50 - 60Hz

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

NCN150

Main Product Image

Code

1762763

Catalog number

NCN150

Type

Miniature circuit breaker (MCB)

Manufacturer

Hager

Serie

-

Neto WSP:

9,76

RP:12,20
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Width in number of modular spacings

1

Rated current

50A

Rated voltage

400V

Built-in depth

70mm

Release characteristic

C

Number of protected poles

1

Over voltage category

3

Number of poles (total)

1

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Additional equipment possible

Frequency

50 .. 60Hz

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

From same serie

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.