Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
40kA
Adjustment range short-term delayed short-circuit release
0 - 0A
Rated permanent current Iu
250A
Power loss
48W
Device construction
Built-in device fixed built-in technique
Overload release current setting
160 - 250A
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
1250 - 2750A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
Rated voltage
220 - 415V
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
No
With switched-off indicator
No
Number of poles
3
Complete device with protection unit
Yes
Motor drive integrated
No
Type of control element
Toggle
Position of connection for main current circuit
Front side
Motor drive optional
Yes
Degree of protection (IP)
IP40
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
HNB250H
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
40kA
Adjustment range short-term delayed short-circuit release
0 .. 0A
Rated permanent current Iu
250A
Power loss
48W
Device construction
Built-in device fixed built-in technique
Overload release current setting
160 .. 250A
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
1250 .. 2750A
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
Rated voltage
220 .. 415V
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
With switched-off indicator
Number of poles
3
Complete device with protection unit
Motor drive integrated
Type of control element
Toggle
Position of connection for main current circuit
Front side
Motor drive optional
Degree of protection (IP)
IP40