Technical specifications
Rated permanent current Iu
160A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
40kA
Rated voltage
220 - 415V
Adjustment range short-term delayed short-circuit release
0 - 0A
Overload release current setting
100 - 160A
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
No
Power loss
32.6W
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
DIN rail (top hat rail) mounting optional
Yes
Number of poles
4
Position of connection for main current circuit
Front side
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
960 - 2080A
Motor drive optional
Yes
Degree of protection (IP)
IP40
With switched-off indicator
No
Type of electrical connection of main circuit
Screw connection
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Type of control element
Toggle
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
HNB162H
![Main Product Image](https://assets.aleta.hr/300x300/5880184b-a666-46a4-a001-379b8b057423_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Rated permanent current Iu
160A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
40kA
Rated voltage
220 .. 415V
Adjustment range short-term delayed short-circuit release
0 .. 0A
Overload release current setting
100 .. 160A
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Power loss
32.6W
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
DIN rail (top hat rail) mounting optional
Number of poles
4
Position of connection for main current circuit
Front side
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
Adjustment range undelayed short-circuit release
960 .. 2080A
Motor drive optional
Degree of protection (IP)
IP40
With switched-off indicator
Type of electrical connection of main circuit
Screw connection
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Type of control element
Toggle
Complete device with protection unit