![Main Product Image](https://assets.aleta.hr/415x415/7f407da4-cdd8-46a8-892a-1066e4cf46f8.webp)
![Main Product Image](https://assets.aleta.hr/415x415/7f407da4-cdd8-46a8-892a-1066e4cf46f8.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Adjustment range short-term delayed short-circuit release
A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
40kA
Rated permanent current Iu
80A
Overload release current setting
50 - 80A
Device construction
Built-in device fixed built-in technique
Power loss
32.1W
Rated voltage
220 - 415V
Adjustment range undelayed short-circuit release
1000 - 1000A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
Yes
Integrated earth fault protection
No
With integrated under voltage release
No
With switched-off indicator
Yes
Type of electrical connection of main circuit
Screw connection
Complete device with protection unit
Yes
Motor drive integrated
No
Degree of protection (IP)
IP40
Motor drive optional
No
Type of control element
Toggle
Position of connection for main current circuit
Front side
Number of auxiliary contacts as change-over contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
HNA080H
![Main Product Image](https://assets.aleta.hr/300x300/8b677e15-e8b8-47cf-8c8c-d1d83547c61a_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Adjustment range short-term delayed short-circuit release
A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
40kA
Rated permanent current Iu
80A
Overload release current setting
50 .. 80A
Device construction
Built-in device fixed built-in technique
Power loss
32.1W
Rated voltage
220 .. 415V
Adjustment range undelayed short-circuit release
1000 .. 1000A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
With integrated under voltage release
With switched-off indicator
Type of electrical connection of main circuit
Screw connection
Complete device with protection unit
Motor drive integrated
Degree of protection (IP)
IP40
Motor drive optional
Type of control element
Toggle
Position of connection for main current circuit
Front side
Number of auxiliary contacts as change-over contact
0
From same serie
Related products