![Main Product Image](https://assets.aleta.hr/415x415/e7d475ed-94c3-41aa-aecd-8eee59345532.webp)
![Main Product Image](https://assets.aleta.hr/415x415/e7d475ed-94c3-41aa-aecd-8eee59345532.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Adjustment range short-term delayed short-circuit release
A
Rated permanent current Iu
63A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
40kA
Power loss
30W
Overload release current setting
40 - 63A
Rated voltage
220 - 415V
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
No
Type of electrical connection of main circuit
Screw connection
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Yes
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
With switched-off indicator
Yes
Type of control element
Toggle
Motor drive integrated
No
Position of connection for main current circuit
Front side
Complete device with protection unit
Yes
Motor drive optional
No
With integrated under voltage release
No
Degree of protection (IP)
IP40
Adjustment range undelayed short-circuit release
1000 - 1000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
HNA063H
![Main Product Image](https://assets.aleta.hr/300x300/33158fb9-100a-400d-a037-6ac244f4a10d_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Adjustment range short-term delayed short-circuit release
A
Rated permanent current Iu
63A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
40kA
Power loss
30W
Overload release current setting
40 .. 63A
Rated voltage
220 .. 415V
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Type of electrical connection of main circuit
Screw connection
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
With switched-off indicator
Type of control element
Toggle
Motor drive integrated
Position of connection for main current circuit
Front side
Complete device with protection unit
Motor drive optional
With integrated under voltage release
Degree of protection (IP)
IP40
Adjustment range undelayed short-circuit release
1000 .. 1000A