Aleta.hr
Main Product Image

HMC499

Code: 1761904

ManufacturerRAZNO
Catalog numberHMC499
Type
EAN code3250613230241

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Built-in depth

70mm

Release characteristic

C

Number of poles (total)

4

Number of protected poles

4

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC

Power loss

42.25W

Flush-mounted installation

Yes

Concurrently switching neutral conductor

No

Current limiting class

3

Rated voltage

415V

Pollution degree

3

Degree of protection (IP)

IP20

Over voltage category

3

Additional equipment possible

Yes

Width in number of modular spacings

6

Ambient temperature during operating

-25 - 70°C

Explosion-proof

No

Connectable conductor cross section solid-core

1 - 70mm²

Connectable conductor cross section multi-wired

1 - 50mm²

Rated current

125A


Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

HMC499

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • HAGER

Technical specifications

Built-in depth

70mm

Release characteristic

C

Number of poles (total)

4

Number of protected poles

4

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC

Power loss

42.25W

Flush-mounted installation

Concurrently switching neutral conductor

Current limiting class

3

Rated voltage

415V

Pollution degree

3

Degree of protection (IP)

IP20

Over voltage category

3

Additional equipment possible

Width in number of modular spacings

6

Ambient temperature during operating

-25 .. 70°C

Explosion-proof

Connectable conductor cross section solid-core

1 .. 70mm²

Connectable conductor cross section multi-wired

1 .. 50mm²

Rated current

125A

From same serie

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.