Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as reversing switch
Yes
Version as emergency stop installation
No
Number of switches
1
Max. rated operation voltage Ue AC
415V
Rated permanent current at AC-23, 400 V
80A
Rated short-time withstand current lcw
1.5kA
Switching power at 400 V
52kW
Rated permanent current Iu
80A
Voltage release optional
No
Rated operating voltage
380 - 415V
Device construction
Built-in device fixed built-in technique
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
Motor drive optional
No
Suitable for front mounting 4-hole
No
Number of poles
4
Version as safety switch
Yes
Type of control element
Short thumb-grip
Conditioned rated short-circuit current Iq
50kA
Suitable for distribution board installation
Yes
Suitable for front mounting centre
No
Interlockable
Yes
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Yes
Degree of protection (IP), front side
IP20
Suitable for intermediate mounting
No
Colour control element
Grey
Type of electrical connection of main circuit
Screw connection
Rated permanent current at AC-21, 400 V
80A
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-23, 400 V
36kW
Degree of protection (NEMA)
Other
From same serie
HIM408

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as main switch
Version as maintenance-/service switch
Version as reversing switch
Version as emergency stop installation
Number of switches
1
Max. rated operation voltage Ue AC
415V
Rated permanent current at AC-23, 400 V
80A
Rated short-time withstand current lcw
1.5kA
Switching power at 400 V
52kW
Rated permanent current Iu
80A
Voltage release optional
Rated operating voltage
380 .. 415V
Device construction
Built-in device fixed built-in technique
Motor drive integrated
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Suitable for front mounting 4-hole
Number of poles
4
Version as safety switch
Type of control element
Short thumb-grip
Conditioned rated short-circuit current Iq
50kA
Suitable for distribution board installation
Suitable for front mounting centre
Interlockable
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Degree of protection (IP), front side
IP20
Suitable for intermediate mounting
Colour control element
Grey
Type of electrical connection of main circuit
Screw connection
Rated permanent current at AC-21, 400 V
80A
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-23, 400 V
36kW
Degree of protection (NEMA)
Other
From same serie
We use cookies to enhance your experience.