Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Number of switches
1
Version as reversing switch
Yes
Version as emergency stop installation
No
Rated operating voltage
380 - 415V
Version as safety switch
Yes
Max. rated operation voltage Ue AC
415V
Rated permanent current at AC-21, 400 V
250A
Rated permanent current Iu
250A
Rated permanent current at AC-23, 400 V
200A
Switching power at 400 V
164kW
Rated short-time withstand current lcw
15kA
Rated operation power at AC-23, 400 V
90kW
Conditioned rated short-circuit current Iq
50kA
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Yes
Number of poles
4
Voltage release optional
No
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Motor drive optional
No
Suitable for intermediate mounting
No
Suitable for distribution board installation
Yes
Device construction
Built-in device fixed built-in technique
Interlockable
Yes
Type of control element
Other
Colour control element
Other
Degree of protection (IP), front side
IP00
Type of electrical connection of main circuit
Cable clamp
Degree of protection (NEMA)
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
HIC425G
Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- HAGER
Technical specifications
Version as main switch
Version as maintenance-/service switch
Number of switches
1
Version as reversing switch
Version as emergency stop installation
Rated operating voltage
380 .. 415V
Version as safety switch
Max. rated operation voltage Ue AC
415V
Rated permanent current at AC-21, 400 V
250A
Rated permanent current Iu
250A
Rated permanent current at AC-23, 400 V
200A
Switching power at 400 V
164kW
Rated short-time withstand current lcw
15kA
Rated operation power at AC-23, 400 V
90kW
Conditioned rated short-circuit current Iq
50kA
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Number of poles
4
Voltage release optional
Number of auxiliary contacts as change-over contact
0
Suitable for floor mounting
Suitable for front mounting 4-hole
Suitable for front mounting centre
Motor drive optional
Suitable for intermediate mounting
Suitable for distribution board installation
Device construction
Built-in device fixed built-in technique
Interlockable
Type of control element
Other
Colour control element
Other
Degree of protection (IP), front side
IP00
Type of electrical connection of main circuit
Cable clamp
Degree of protection (NEMA)
Other
From same serie