![Main Product Image](https://assets.aleta.hr/415x415/f67fc7c1-00bb-40ba-9428-c12f12a1a96b.webp)
![Main Product Image](https://assets.aleta.hr/415x415/f67fc7c1-00bb-40ba-9428-c12f12a1a96b.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Adjustment range short-term delayed short-circuit release
A
Overload release current setting
50 - 80A
Rated permanent current Iu
80A
Type of electrical connection of main circuit
Screw connection
Power loss
32.1W
Adjustment range undelayed short-circuit release
1000 - 1000A
Rated voltage
220 - 415V
Suitable for DIN rail (top hat rail) mounting
Yes
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25kA
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Position of connection for main current circuit
Front side
Number of poles
3
Device construction
Built-in device fixed built-in technique
With integrated under voltage release
No
Motor drive integrated
No
Type of control element
Toggle
Motor drive optional
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP40
Integrated earth fault protection
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
HHA080H
![Main Product Image](https://assets.aleta.hr/300x300/46503ca0-3892-4ca9-9f17-2535c9fd37fb_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Adjustment range short-term delayed short-circuit release
A
Overload release current setting
50 .. 80A
Rated permanent current Iu
80A
Type of electrical connection of main circuit
Screw connection
Power loss
32.1W
Adjustment range undelayed short-circuit release
1000 .. 1000A
Rated voltage
220 .. 415V
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
25kA
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Position of connection for main current circuit
Front side
Number of poles
3
Device construction
Built-in device fixed built-in technique
With integrated under voltage release
Motor drive integrated
Type of control element
Toggle
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP40
Integrated earth fault protection