![Main Product Image](https://assets.aleta.hr/415x415/813444c1-e4d5-461d-accc-3d7ec2c8f216.webp)
![Main Product Image](https://assets.aleta.hr/415x415/813444c1-e4d5-461d-accc-3d7ec2c8f216.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Rated voltage
220 - 690V
Power loss
187.50W
Overload release current setting
500 - 1250A
Adjustment range short-term delayed short-circuit release
0 - 0A
Adjustment range undelayed short-circuit release
7000 - 15000A
Rated permanent current Iu
1250A
Integrated earth fault protection
No
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Number of auxiliary contacts as change-over contact
0
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
No
Number of poles
3
With integrated under voltage release
No
Motor drive optional
Yes
Position of connection for main current circuit
Front side
Motor drive integrated
No
Complete device with protection unit
Yes
Degree of protection (IP)
IP40
Type of control element
Toggle
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
HEF980H
![Main Product Image](https://assets.aleta.hr/300x300/50a9d6c1-b120-4b43-9f40-e91d585d4fff_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- HAGER
Technical specifications
Rated voltage
220 .. 690V
Power loss
187.50W
Overload release current setting
500 .. 1250A
Adjustment range short-term delayed short-circuit release
0 .. 0A
Adjustment range undelayed short-circuit release
7000 .. 15000A
Rated permanent current Iu
1250A
Integrated earth fault protection
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Screw connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Number of auxiliary contacts as change-over contact
0
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Number of poles
3
With integrated under voltage release
Motor drive optional
Position of connection for main current circuit
Front side
Motor drive integrated
Complete device with protection unit
Degree of protection (IP)
IP40
Type of control element
Toggle
From same serie